rouggy c5c9d355ec fix(logging): name the antenna disagreement, and confirm an outbound send
Two silences from one operator's log.

The SteppIR is not blocked — it is being overruled. Every tune is commanded,
acknowledged on the next poll with the frequency asked for, then replaced on
the poll after by a different one: 21075 asked, 21075 confirmed, 21050
reported, again and again, with the operator tuning once more each time. Two
minutes of that reads as a dead link. It now says what it is, once, when the
motors have stopped and the reported frequency is more than 10 kHz from the
commanded one — a controller quantising to its own grid is not a fault, one
sitting somewhere else entirely is.

UDP outbound had no positive signal at all: only failures were logged. When
an operator sets up an ADIF message to a second logger and nothing arrives,
"OpsLog never sent it" and "the other program did not take it" looked exactly
the same from here — and the first is the common case, because a row created
as an inbound ADIF listener instead of an outbound ADIF message matches
nothing and emits nothing. Successful sends are logged with their destination
and service, and a QSO logged with no outbound row says so once a session.
2026-08-14 17:37:12 +02:00