Switching an SPE amp off left the already-open connection reading as connected
(the amp stops answering once off, but the stale open handle kept the status at
"connected"), so the panel never showed OFF and PowerOn — which only wakes a
DISCONNECTED amp, and must NOT pulse RTS/DTR on a running one — did nothing
until the operator restarted OpsLog. PowerOff now drops the connection and marks
the amp offline, exactly as a fresh start would; the poll's plain reopen never
wakes a switched-off amp, so it stays off until the ON button's RTS/DTR edge.
Implements the SPE Application Programmer's Guide protocol: packets
0x55 0x55 0x55|CNT|DATA|CHK (sum%256), OPERATE key 0x0D (toggles STANDBY/OPERATE)
and STATUS request 0x90 whose 0xAA-framed reply is a 19-field CSV (mode, RX/TX,
band, power level, output W, SWR, V/I, temp, warnings, alarms). internal/spe
polls status ~1/s over USB serial (go.bug.st/serial, 8N1) or TCP (RS232-to-
Ethernet bridge) — same codec, different transport.
Wired via startPGXL (starts the SPE client for spe* types), bindings GetSPEStatus
/ SPESetOperate, and a live status card + OPERATE/STANDBY toggle in the Amplifier
settings panel. Only the two example-anchored commands are sent (safe); other
keystroke codes were ambiguous in the guide's table. Untested on hardware.