rouggy 6aff322be6 chore(spe): make a failed power-on say where it failed
"The ON button does nothing" has three different causes — the modem-line pulse
was refused, the pulse went out and the amplifier ignored it, or the amplifier
woke and the UI missed it — and the log could not separate them: it recorded
one combined error and never said whether the amp came up.

RTS and DTR are now reported separately (not every USB-serial chip honours the
modem lines, and some refuse them without saying so), alongside the model and
transport. A watcher then logs whether the amplifier answered within 15
seconds, off the caller's goroutine so the click still returns at once.

No change to the wake sequence itself, which is the part that took a long time
to get right on the 1.3K-FA.
2026-08-13 09:29:53 +02:00
rouggy 385e8c4c86 fix: log the grid the station sent, and show the SPE going off first press
Grid: RI0FA transmitted QN35 all evening and was logged with its licence
holder's home square. WSJT-X's logged ADIF usually carries no GRIDSQUARE, so
the lookup was the only source left — and QRZ/HamQTH describe where an operator
LIVES, which for an expedition is the wrong side of the planet.

The square heard on the air is now applied before the lookup runs, so
refineGrid has something to defend. It still upgrades a 4-character square to a
6-character one from the same field, and still refuses a finer square from a
different field.

SPE: decodeCSV marks the client connected on every frame it parses, and the
poll goroutine can be mid-read while PowerOff runs. The frame from a second ago
landed after PowerOff had marked the amp offline and put it straight back,
which is why OFF had to be pressed twice.

Frames are ignored for three seconds after the off key goes out — the window is
opened before the key is sent, so nothing already travelling can beat it. Time
bounded rather than latched: an amp switched back on at its own front panel has
to reappear without being told.
2026-08-13 09:08:19 +02:00
rouggy a20d9a0b76 fix(spe): drop the link on power-off so status shows off and ON works
Switching an SPE amp off left the already-open connection reading as connected
(the amp stops answering once off, but the stale open handle kept the status at
"connected"), so the panel never showed OFF and PowerOn — which only wakes a
DISCONNECTED amp, and must NOT pulse RTS/DTR on a running one — did nothing
until the operator restarted OpsLog. PowerOff now drops the connection and marks
the amp offline, exactly as a fresh start would; the poll's plain reopen never
wakes a switched-off amp, so it stays off until the ON button's RTS/DTR edge.
2026-08-05 11:02:44 +02:00
rouggy f6cd6e999a chore: release v0.22.9 2026-08-02 06:40:10 +02:00
rouggy 2194279602 fix: drain SPE status backlog so display is current (was ~15s stale); ON now pulses DTR (0x0B is level-only); power-level cycle waits for real status change 2026-07-21 01:38:39 +02:00
rouggy 7d7d175ede feat: SPE amp ON/OFF buttons and Low/Mid/High power-level control (keystroke codes best-guess from APG, pending hw verification) 2026-07-21 01:25:55 +02:00
rouggy be1ae76eb3 fix: correct SPE band-code map (00=160m,01=80m,02=60m...confirmed on hw); add output-power bar to SPE amp card 2026-07-21 01:19:24 +02:00
rouggy fe1a77a54d fix: use official SPE band-code table from the manual (00=60m,01=160m,...) 2026-07-21 01:10:12 +02:00
rouggy b818a2d947 fix: correct SPE status CSV field alignment (leading empty field shifts indices +1); decode band code; OPERATE/STANDBY now reflects real amp state 2026-07-21 01:09:13 +02:00
rouggy 42a6b9c76a debug: log raw SPE status frame on change (to verify CSV field alignment on real hw) 2026-07-21 00:54:13 +02:00
rouggy 2e39615554 feat: SPE Expert amplifier control (serial/TCP) — OPERATE toggle + live status
Implements the SPE Application Programmer's Guide protocol: packets
0x55 0x55 0x55|CNT|DATA|CHK (sum%256), OPERATE key 0x0D (toggles STANDBY/OPERATE)
and STATUS request 0x90 whose 0xAA-framed reply is a 19-field CSV (mode, RX/TX,
band, power level, output W, SWR, V/I, temp, warnings, alarms). internal/spe
polls status ~1/s over USB serial (go.bug.st/serial, 8N1) or TCP (RS232-to-
Ethernet bridge) — same codec, different transport.

Wired via startPGXL (starts the SPE client for spe* types), bindings GetSPEStatus
/ SPESetOperate, and a live status card + OPERATE/STANDBY toggle in the Amplifier
settings panel. Only the two example-anchored commands are sent (safe); other
keystroke codes were ambiguous in the guide's table. Untested on hardware.
2026-07-20 17:59:24 +02:00