Asked whether the faster poll applies to all the rotator backends. It does —
GetRotatorHeading is one binding over PstRotator, Rotator Genius, GS-232/ARCO,
DCU-1 and SPID alike, and it reads only the ACTIVE rotor, so two towers do not
double it. But counting what that costs turned up two things worth fixing.
Every backend builds a fresh client per call — spid.New, gs232.NewSerial,
dcu1.NewSerial, rotgenius.New — so one poll is one OPEN and CLOSE of a serial
port or a TCP connection, not a read on a link already up. And the status bar
and the Station Control compass each ran their own interval against that same
binding, so with the tab open the controller was asked twice over. At the 700 ms
I had just set, that was nearly three port opens a second on a 600-baud line.
Both now share one loop, and it adapts: 500 ms while the position is changing,
3 s once it has been still for six seconds. These controllers do not report
"moving" — a SPID answers a position and nothing else — so it is inferred from
the position itself, and held briefly after the last change so the tail of a
movement stays smooth. Commanding a move, a stop, or switching rotor polls at
once, so the needle starts sweeping on the click.
A slow controller cannot stack requests behind itself either: at 600 baud a SPID
reply takes a fifth of a second on the wire alone, and a port still open from
the last poll cannot be opened again.
Field report from a tower: on a RAK/RAU in Rot1Prog, every commanded heading
made the antenna want to turn nearly a full circle ANTICLOCKWISE — 0°, 90°, any
of them — while the heading readout, the stop button and everything else worked.
BuildSet framed the four-digit Rot2Prog azimuth for both dialects. A Rot1Prog
reads three: its replies are three digits in a five-byte frame, and its command
field matches. So 90° went out as "0450" and was read as 045 — 45 − 360 = −315°.
Every target landed 360° low, which is why it was always anticlockwise and
always nearly a full turn. The operator's own guess, that OpsLog was in 720°
mode, was the right instinct in the wrong place: the fault is a decimal shift,
not a range.
The round-trip test added here is the one that would have caught it without a
tower — every degree of the circle through the command builder and back through
the reply parser, which must return the degree that went in. The frame tests
pinned the Rot2Prog form against the reference and said nothing about the other
dialect.
Two more from the same report. A rotator test that only READS the heading — SPID,
ARCO, DCU-1 — said "Packet sent, the antenna should swing to north, check
PstRotator's UDP listener", naming a program not in the path for a move never
commanded; it now says the controller answered and nothing was moved. And the
compass polled every three seconds, so a turning antenna moved the needle in
steps of about thirteen degrees; the heading now has its own 700 ms tick while
the relay boards and the antenna controller stay at three seconds.
It held a useState and a useEffect of its own, and the panels in that registry
are called as plain functions — PANELS[x]() — not rendered as elements. So its
hooks landed in SettingsModal's own hook list, and only while that section was
open: React counted more hooks than the render before and stopped drawing the
whole window (error #310).
The file says so three lines above the entry I added, on the two panels that DO
carry hooks and are therefore wrapped in JSX. Reading it would have been quicker
than the screenshot.
No hook here now. The COM ports come from the list SettingsModal already loads
when it opens, for the Winkeyer panel — one machine, one set of serial ports,
fetched once instead of twice.
The manufacturer's document arrived, so this is no longer guesswork: 9600 8N1,
function codes 03 and 06 only, and a register map with the output on/off at
0x0001, the measurements at 0x0010…0x0013 and the set points at 0x0030/0x0031.
ONE REGISTER IS WRITTEN — 0x0001, the output. The map also exposes the voltage
and current set points and the three protection trip levels as writable, and
none of them belong to a logbook: a wrong value there is 30 V where a radio
expected 13.8, or a trip level lifted on a supply feeding an amplifier. They are
read and displayed instead, next to the measured values, which is also how an
operator sees at a glance that the supply is on and the radio is drawing nothing.
The wire layer is tested where it can be. CRC-16/MODBUS is pinned against its
published check value — the CRC of "123456789" is 0x4B37 — which fixes the
polynomial, the initial value, the reflection and the absence of a final xor all
at once; the rest of the protocol is checked frame by frame against the manual,
including the byte order of the CRC, an exception reply told apart from a broken
line, and a reply from another slave on the bus refused. The write echo must
match the value sent: it is the only confirmation the output really switched,
and accepting the frame without it is how a radio ends up dark behind a green
light.
Framing follows the manual's own rules: 3.5 character times of silence between
frames (4 ms at 9600), and a frame is over when the line falls quiet — Modbus
RTU has no terminator, and a serial read that times out returns (0, nil) here,
so the reader is built on a deadline and a quiet-time rather than on an error
that never comes.
Untested against hardware — nobody here has the supply.
Relay automatic control and the band-change outbound rows both hang off the rig
state, which is right when there IS a rig: changing Band in the entry strip
pushes a QSY, the new state comes back through the CAT callback, and the relays
follow from there — which is why this works for anyone with rig control.
Without a CAT connection nothing is pushed and nothing comes back, so a station
whose rig OpsLog does not control changed band and the antenna switch sat
exactly where it was. Reported as automatic control not working; it was never
told the band had changed.
The entry selector now says so itself, but only when the CAT push did not
happen, and never when the band or frequency lock is on: a lock means the entry
is deliberately decoupled from the rig, and moving an antenna to match a contact
logged from last year is worse than doing nothing.
The frequency is passed as unknown on that path — a band selector gives a band
and nothing else, and rules written on a frequency RANGE are left alone rather
than evaluated against a made-up dial reading.
The de-duplication of "is this a new band" is now shared by both sources, so a
station that has both does not command its switch twice for one QSY.
Also: the same credit line as the QSL e-mail now closes the default recording
e-mail body, on the same terms — a default in the template, so a stored one is
untouched.
Reported as delayed auto-upload breaking Recent QSOs. It does not — the grid was
waiting on the upload for its news.
Nothing reloaded the list on qso:logged. The entry form calls refresh() itself
after AddQSO, so a QSO TYPED in OpsLog always appeared; a QSO logged from
anywhere else — WSJT-X or MSHV over UDP, JTAlert, NET Control, an offline replay
— reached the grid only when something else reloaded it, and the something else
was extsvc:uploaded. With auto-upload set to immediate that arrives a second
later and hides the gap completely.
Set a service to delayed and the QSO appeared one to two minutes late; set it to
upload on close and not until the next launch. So the very thing deferring an
upload exists for — correcting a contact before it goes out — was impossible,
because there was nothing on screen to correct.
The list now follows the log, on the same debounced path the upload events
already use: qso:logged fires twice per contact (insert, then award refs) and a
contest run fires it every few seconds.
The automatic pass fills a blank county only, and deliberately: a value the
operator or QRZ supplied usually beats one derived from a ZIP code. That leaves
no way at all to correct a county already stored — and the Connecticut planning
regions are exactly that case. Every CT contact logged before that correction
holds a county the state abolished in 2022, and filling blanks never reaches
one of them.
So the new entry OVERWRITES, because it is asked for by hand on a chosen set of
rows precisely because the stored value is believed wrong. Only US entities are
touched, only callsigns the database holds, and only when the answer actually
differs — so re-running it on a mixed selection is safe and the count reported
is the number of counties that really changed. Award refs are re-materialised:
the county IS the reference for CQ USA-CA and the state for WAS.
The entry appears only once the database has been downloaded, and appears
without a restart when one finishes — an action that can only ever answer "no
database" is not worth a line in a menu this long.
It was built the other way round on a misreading of two screenshots: the pattern
held {value} and the per-relay boxes held numbers to drop into it. The ask was
simpler and better — {value} is the name typed in Relay labels, so a switch
addressed by antenna name is one pattern instead of eight URLs:
http://10.10.10.100/relay?on={value} relay 1 named Ant1 → ?on=Ant1
Renaming the antenna re-addresses it, and the name on the button and the name on
the wire cannot drift apart because they are the same string. It works in the
per-relay URLs and in the patterns alike, so the per-relay boxes go back to
holding URLs and nothing about them changes meaning any more.
The label is percent-encoded with %20 rather than "+" for a space: "+" is a
space only in a query string and a literal plus in a path, and this can land in
either half of a URL.
{value} on a relay with no label would send "?on=", an empty parameter that most
boards answer with a cheerful 200 and no movement. The driver refuses it and
names the label as what is missing; the editor warns while it is being typed,
beside the empty box rather than after an antenna fails to switch. The labels
also join the driver's cache key — they are part of the wire format now.
They were made session-only on a misreading: the ask was about the FIRST launch
of a fresh install, not every launch. Restored as they were — restored on
reopen, and travelling with a copied data/ folder.
A first-ever launch already starts with nothing filtered: every selection
defaults to empty or off and there is no code that switches one on. The one
route by which a new installation can come up filtered is a copied data/ folder,
which carries the previous machine's selections by design.
The filtered-out message and the clear-every-filter button stay: they are what
makes a filter that IS set visible, whenever it was set.
buildDeviceDriver had no case for "httpgen", so the generic board fell through
to the WebSwitch driver: it polled an address it had never been given, reported
itself offline, greyed out every relay button, and sent none of the configured
URLs. Nothing in the interface said so — the board was configured, saved and
listed, and simply did nothing. deviceKey did not cover the URLs either, so once
that is fixed, correcting a typo in one would still have handed back the cached
driver holding the old address until a restart.
Two shapes of home-made switch could not be described at all:
- a bit-mask board whose four URLs differ by one character
(/Set0/1, /Set0/2, /Set0/4, /Set0/8) — {value} in the pattern now takes the
number from the per-relay box, keeping the address in one place;
- a board numbering its channels from zero — {relay-1}, since giving up the
pattern for eight hand-typed URLs was the only alternative.
The pattern decides what the per-relay boxes hold, and the grid says which as
soon as {value} is typed: guessing per box ("does this look like a URL?") would
change meaning on a typo, which is not a thing to do to something wired to an
antenna. A URL typed without a scheme gets http:// like the named boards get
from relayBase; https:// is passed through untouched.
Host and the connection test are gone for this type. It has no address of its
own — its relays may each live on a different box — and no status to read, so a
test could only ever answer "OK, 4 relays". Save was greyed out without a host,
which made a complete configuration of four full URLs impossible to store.
Cluster filters no longer persist across launches. A band lock set weeks earlier
is invisible to whoever set it: the counter reads 76 spots live, the grid is
empty, and the search goes to the cluster instead. Nobody loses work by
re-ticking a chip. Grouping and the panel state still persist — they change how
spots look, never whether they appear.
An operator sent two screenshots: 76 LIVE in the counter, and the panel beside
it reading "Waiting for spots… Spots will appear as the cluster sends them."
Both his band and mode were locked to the rig — 20 m, SSB — so the filters were
doing exactly their job and the empty state was describing a different problem
entirely. He went looking for a connection fault.
It now says how many arrived, names every filter currently narrowing the list,
and offers one button to clear them all. The band and mode locks are named
first: they follow the rig rather than a click, so they are the two nobody
remembers switching on.
Also times the connection. He reports the first launch taking a while to
produce spots and a restart connecting instantly, which is the signature of a
slow name resolution rather than a slow node — the OS caches the answer, so the
second run skips it. The log now carries the dial duration and the delay to the
first spot, which separates that from a node that simply had nothing to say.
Hypothesis, not conclusion: the next log settles it.
Same bug as yesterday's, one screen further on. The QSL Info table maps the
statuses it knows — Y, R, I, M — and falls through to "No" for anything else.
ADIF's V is anything else. So a contact confirmed AND validated by LoTW was
reported as not received, in the one place an operator opens to check.
V now has its own label, Verified, in the green of a confirmation, and it is in
the dropdown too. That second half matters more than it looks: a select whose
value is not among its items renders blank, so a verified contact looked like
nothing had been recorded — and the operator's next click would have replaced
the strongest confirmation they hold with whatever they picked instead.
The QSL Manager's bulk list is deliberately left alone: it sets paper QSL
status across a selection and defaults to "leave", so it never displays a
stored value, and "verified" is not something a paper card can be.
An operator with a tower at each end and an AlfaSpid on both wanted OpsLog to
talk to them directly. Multiple rotors were already there; the missing half was
the protocol.
Rot2Prog and Rot1Prog, over the controller's own COM port. The byte layout is
in the package doc and pinned by table tests against Hamlib's spid.c, the
reference implementation — including the one trap this protocol has: digits go
out as ASCII and come back as raw bytes. Send raw and the controller ignores
you; read as ASCII and every heading is wrong by a constant nobody would
recognise as such.
Two things the UI has to get right because they cannot be detected: the dialect
(different reply length AND baud rate) and the baud list, which for a SPID is
600 or 1200 — offering the usual 4800-and-up would have left the controller
permanently mute. Both are handled: picking SPID sets serial transport, 600
baud and Rot2Prog, and the baud dropdown changes to the rates these use.
The connection test reads a status rather than moving anything, so a wrong
dialect shows up there as a reply of the wrong length instead of as an antenna
that behaves oddly an hour later.
Untested against real hardware — I have none. The frames are pinned; the
controller is the only thing that can confirm the rest.
An operator's screenshot had it side by side: the Awards panel showed Morocco
validated on five bands, and the band/mode matrix two inches above showed the
entity as merely worked.
ADIF's QSL_Rcvd enumeration has both Y and V — "received" and "verified" — and
V is what a LoTW download writes for a confirmation the ARRL has validated. The
award engine's isYes accepted "Y" or "V". Everything else in the app compared
against 'Y' alone: the worked-before status grid, the slot statistics, the row
colouring by QSL status, the awards QSO list, the call history badges. So the
confirmations an operator cares most about were the ones that did not count.
Now one definition per side, named so the next reader finds the other:
qso.ConfirmedValues on the Go side, used by the queries themselves, and
isQSLConfirmed in lib/qsl on the frontend, which rowColors and the panels call
instead of testing the letter.
The Go test drives the real query shape against a real database with a 'V' row
— the constant being right is not the point, the queries using it is.
The selector offered 1, 2, 4, 8 and 16 and none of them took: the board stayed
at four relays.
The count is decided in three places — deviceRelayCount in Go, chanCount in the
Station Control panel, relayCountUI in Settings. The new type was added to the
first and the dropdown, and to neither of the others, so the panel resized the
labels from a helper that had never heard of it and fell straight through to
its fixed default. The Go side was right the whole time, which is why the
driver would have been built correctly for a count the operator could not set.
All three now know the type. A test pins the Go side against every count the
dropdown offers, and against the fixed boards, whose hardware decides and which
must keep ignoring the field.
An operator was about to build band→relay mapping into the custom URL rows.
It already exists, and better: relay auto-control has a per-relay "band" rule
driving webswitch, KMTronic, Dingtian, Denkovi and USB boards. It holds state
so a relay is only commanded when its wanted position changed, reads the
boards live before the first apply so it does not re-command one already in
place, and carries per-relay labels. A URL fired on a band change has none of
that, and would have been a second definition of "which antenna on which band"
— the drift that cost us a week on counties.
So the gap was only the hardware: a hand-made switch is none of the five named
types. It is now the sixth, "HTTP relay": an ON URL and an OFF URL, either as
one pattern with {relay} substituted, or one pair per relay. The per-relay
form is the reason it exists — these boxes often have URLs with nothing in
common between channels (…/FF0101 and …/FF0201), which no pattern can express.
Status is remembered rather than read: most have no endpoint worth trusting.
The cost is stated in the code and the panel — after a restart every relay is
re-commanded once, which is harmless on a board with no memory and far better
than assuming an antenna is already selected.
And the Connections panel now says so, exactly where the wrong choice is made:
picking a band change with a URL transport shows a note pointing at Station
Control. The URL transport stays — a lookup pushed to a webhook or a QSO to a
dashboard is an event, not a state, and Station Control has no place for it.
Two answers to "can people debug this when it does not work".
They could not. A custom UDP row logged "sent 18 bytes to 127.0.0.1:12000"
and nothing about the message — which is a template the operator wrote, so
the byte count says nothing about whether the substitution came out as they
meant. The payload is now in the line, with the trigger that fired it, for
custom rows only: an ADIF record or a binary WSJT frame on every QSO would
bury the log rather than fill it.
Worse was the silent case. A template that is a single placeholder the trigger
does not carry — {freq} on a band change — renders empty, sends nothing, and
looked exactly like a row that had never fired. It now says so, throttled per
row, and points at the field list.
And a password in a URL is redacted before it reaches the file. Storing
http://admin:secret@switch/ as typed was a deliberate choice for LAN gear;
writing it into a log that gets sent to whoever is helping is a different
choice, and was never made.
The Settings section is "Connections" rather than "UDP integrations", since it
has not been UDP-only since the URL transport landed. The log prefix stays
"udp:" on purpose — renaming it would orphan every log an operator has already
sent and every note anyone has written against it.
The hard-coded emitters each speak one published format at one fixed moment.
This is the escape hatch, and it exists mainly for antenna switches: they are
driven by a URL, and the band change is the trigger they want.
Four triggers, each carrying its own field set: band change (the RADIO's band,
not the entry form — a switch follows the rig, not what is being typed), QSO
logged, rotator command and callsign lookup. The panel prints the fields the
selected trigger can fill, which is the point of the whole thing: a placeholder
the trigger does not carry renders as nothing, and without the list an operator
writes {freq} on a band change and has no way to learn why the switch never
moved.
Three things the panel cannot show, handled here:
- Escaping. A URL needs every value percent-encoded; a UDP payload must not
be touched. The first portable callsign, F4BPO/P, puts a path separator in
the middle of a query string otherwise — it works on the bench and fails on
the air.
- Blocking. An HTTP call to a switch that is unplugged would otherwise sit
for the operating system's timeout, on the path of a band change. It runs
in the background with a 3 s limit.
- Silence. A switch answering 404 after a firmware update fails exactly like
success looks from here, so the status code is logged, throttled per row.
The rotator trigger hooks the COMMAND rather than the SP/LP buttons, so the
compass and a spot click fire it too, and the path ("SP"/"LP") is passed
through because an azimuth alone cannot say which was taken — 137° is short
path to one station and long to another.
Credentials in a URL are stored as typed. That is the operator's call, on the
grounds that this is LAN gear, and the hint in the panel says so.
"WSJT-X logged QSO (Logger32)" reads as Logger32-only, and it is not: the row
speaks the WSJT-X UDP interface, which several loggers listen on. An operator
running something else would have scrolled past a service that would have
worked for them.
Logger32 stays in the hint as the example it is — it is what this was built
against, and its additional sockets are where most people will point it — and
port 2250 stays as the default, a starting point rather than a rule.
"sent 1153 bytes to 127.0.0.1:2250" and nothing in Logger32. Both true: the
line the operator screenshotted is titled "Setup additional WSJT/JTDX UDP
sockets", and those receivers take UDP LOGGING PACKETS — the WSJT-X v2
protocol. A bare ADIF record posted to them is dropped without a word.
So there is a new outbound service rather than a change to the existing one:
"WSJT-X logged QSO (Logger32)" sends the same ADIF wrapped in a Logged ADIF
datagram (magic 0xadbccbda, schema 2, type 12), defaulting to port 2250. The
plain-text row stays for JTAlert/GridTracker-style receivers, because the two
really are different wire formats and one row cannot be both.
The id string is "OpsLog", not "WSJT-X": a receiver uses it to tell instances
apart, and impersonating the real thing would make a second WSJT-X
indistinguishable from us.
Tested both ways — the header byte for byte, and a round trip back through our
own ParseWSJT, since that is the same decoding every receiver applies.
Sahara moves to the parchment an operator asked for: page #e6ded0, panels
#f3eee2, toolbars #ded5c4, terracotta #c4501e on the buttons and the focus
ring. Lighter and less saturated than the deep sand it was.
The paper form had one "Via", which since the QSL_VIA split writes
QSL_SENT_VIA. QSL_RCVD_VIA had no way in at all outside the per-QSO editor —
a field with a column, an import and an export, and nothing to fill it.
Each direction now has its own route dropdown, sitting with the status and
date it belongs to: how the card was sent, beside Sent; how it came back,
beside Received. Both apply to the whole selection, which is the shape of the
job — a stack confirmed in one go usually arrived the same way, a bureau
delivery being exactly that, and doing it one QSO at a time in the editor was
the only option before.
Both store the ADIF enumeration (B/D/E), and neither touches QSL_VIA — that
holds the manager's callsign and belongs to the QSO, not to a stack of cards
being confirmed together.
The two columns were already available in the paper list: it renders through
RecentQSOsGrid, which gained them with the field itself.
An operator waited over a minute and the button never appeared; opening
Settings and pressing Cancel made it appear at once. That is the whole
diagnosis — Cancel was the only thing that re-read the option.
GetChaseNew returned the cached atomic, which exists for the MQTT goroutine
and is false until startup has read the setting. The UI asked while the
database was still opening, was told "off", believed it, and never asked
again. It now reads the setting, like the grid-chasing binding beside it.
The frontend asks again at the two moments this class of race resolves: when
GetStartupStatus returns, and when the first logbook load succeeds — the seam
that already re-reads the connection label for exactly this reason, with a
comment saying so.
The open/closed state was already remembered per machine; it is now in
PORTABLE_KEYS with the other widget toggles, so it travels with data/ like the
rotor and amplifier panels rather than being the one that does not.
Three cuts, all of them removing things nobody could act on.
The frequency column is gone. Clicking the row tunes the rig to it, so the
number was there to be read and never used. It is still carried on the spot —
the click is what needs it — and it is in the row's tooltip. The country takes
the space.
Modes are limited to FT8, FT4, FT2, PSK31 and RTTY. WSPR is the one worth
spelling out: it is a beacon, nobody answers a WSPR transmission, so a "new
entity on WSPR" is a path report and not a station to work — and on a quiet
band it would have been most of the list.
Bands are limited to the operator's own list. PSK Reporter carries every band
its receivers listen on, and a 13 cm decode is not an opportunity for a station
with no 13 cm.
Both tests run before the status lookup and both read a cached map: they throw
away most of the feed, so nothing downstream pays for it. The band list is
re-read when the lists are saved, so ticking a band in Settings applies to the
next decode rather than the next restart — which would have looked like the
filter not working.
Four things from an operator's first look at the panel, and one of them was
mine.
The frequency column showed "—" on every row. pskr.Spot.FreqHz was declared
and documented in one edit and never assigned in the next, so the payload's
"f" was parsed and dropped. A click therefore filled the callsign and left
the rig where it was, which is half the point of the panel. Assigned, with a
test that runs a real payload through and checks the value survives into the
Spot — the field being declared is what made it look done.
A row now carries ONE indication instead of stacking them. A station can be a
new band and a new prefix at once; the row says the first that matters, in the
order that would make an operator leave what they are doing: entity, band,
mode, slot, then prefix, then square. Two badges on one line made the list
unreadable at a glance, which is the only thing it is for.
Each category has a filter chip in the header, in its own colour, remembered
across sessions. A toolbar button shows the panel and a cross closes it — the
same split the Super Check Partial panel uses, where the setting decides
whether the feature exists and the button whether it is on screen.
The panel is wider and the country column gets what is left, which is more
than it was now that a row carries one badge.
PSK Reporter tells you what is actually being decoded in your region, which
is a larger set than what somebody chose to spot: nobody spots the FT8 caller
running ten watts from a rare square.
Almost all of it existed. The MQTT payload already carries frequency, mode,
transmitter and both grids; the watcher already drops any report collected
further than NearKm from the operator, which is exactly the question worth
asking — the station is being heard HERE, not in Japan; and with grid chasing
on the subscription is already every band, filtered at the broker by receiver
square, measured at 0.2 to 1.2 messages a second. This reads messages that
were arriving and being discarded.
"New" is not decided here. Every spot goes through ClusterSpotStatuses, the
same function the DX cluster grid uses and the same cached index, so the two
panels cannot drift apart the way the county columns did. Cost per message is
map lookups behind an option cached in an atomic, because the MQTT goroutine
must never wait on the settings store.
The option is its own, not nested under grid chasing: chasing squares and
chasing entities are different wants, and the feed now has three consumers,
any one of which brings it up and none of which cuts the others loose when it
goes down.
The panel says "digital modes only" in its footer. An empty list has to mean
"nothing new on FT8/FT4/JS8 near you", not "the band is dead" — it will never
show a new entity on CW.
The comment came out "SSB WAC EU WAZ 15 WPX HA5" — the QSO's materialised
award_refs hold both kinds, and I took them all. Those four are what every
reader of the spot derives from the callsign in their head. They spent the
whole 30-character comment saying nothing and buried SOTA HA/KM-018, the one
reference anyone would have acted on.
Computed awards are now filtered out with the same rule the QSO editor uses
(isComputedAwardField), which is why they are the ones it lists on the left
and not in its read-only panel. The field map moves from a ref to state as
well: a ref left the first spot of a session computing before GetAwardDefs
had answered.
Also opens 0.25.2, since 0.25.1 shipped before the spot work, and sets the
default mode list to SSB, CW, FT8, FT4, FT2, RTTY, PSK31, FM. AM and
DIGITALVOICE stay in the catalogue but are no longer selected on a fresh
install. FT2 joins the digital family everywhere its siblings are listed —
report list, RST defaults, Flex power class — so it gets dB reports rather
than the 59 an unknown mode falls back to.
After the mode, which is the order a cluster line is read in:
"CW POTA FR-11553".
Two sources, because the QSO can be at either stage. While it is being typed
the entry panel holds the references as "CODE@REF;CODE@REF"; once logged they
live on the row as the materialised award_refs. The Send Spot window takes the
entry's when there are any and falls back to the last logged QSO — the same
fallback the callsign and frequency defaults already use — and picking a QSO
from the Latest list fills in that QSO's own.
A self-spot is the opposite case and gets its own builder: it announces OUR
station, so it carries MY_POTA_REF and friends. Using the QSO's award
references there would spot us with the park number of the station we just
worked, announcing us from somewhere we are not.
Both cap at the 30 characters a cluster node keeps, and add a reference whole
or not at all — a truncated park number is worse than none, since nobody can
act on it, and it still costs everyone who reads the spot. Only the comment we
BUILD is held to that; what the operator types is their own business.
The K3NG entry added an hour ago is gone. It named one clone among many —
WKmini, home-built Arduinos, unbranded boxes — for hardware that speaks
exactly the same protocol, and it was the only line in the engine list that
picked a boot delay rather than a protocol. An operator with an unlabelled
clone would have had to guess.
The delay is now learnt per port. The first connect finds out by failing the
quick attempt and succeeding on the slow one; that fact is written to a
global setting keyed by the port, and every connect afterwards goes straight
to the slow attempt. Global rather than per profile on purpose: which keyer
is plugged into COM3 belongs to the computer, and switching profiles for a
different rig does not change the keyer on the desk.
Two tests hold the contract from both sides — a slow keyer must be reported
as slow, and a keyer that answers at once must not be, or every K1EL connect
would inherit seconds it never needed.
The operator's keyer is a K3NG — an Arduino running an emulation of the
WinKeyer protocol — which changes the diagnosis and nearly broke it.
Checked against K3NG's own source before anything else, because yesterday's
handshake now FAILS a connect where it used to press on regardless. It is
safe: k3ng_keyer.ino implements admin echo (0x04) and echoes the byte back,
0x13 is a documented no-op, and OPTION_WINKEY_STRICT_HOST_OPEN — on by
default — ignores every byte except 0x00 before host open, so the resync
nulls are dropped harmlessly and the echo probe still gets through.
The real cause is in K3NG's options file, beside the feature itself:
"disabling Automatic Software Reset is highly recommended", and an option
to "discard errant serial port bytes at startup" for when it is not. On an
Arduino, DTR is wired to reset through a capacitor: opening the port reboots
the board into its bootloader. Ours spoke 400 ms later, to a keyer that was
not running yet.
So the retry now waits 2.5 s, which recovers it without an operator pressing
connect twice, and the engine list gains a K3NG entry that skips the doomed
fast attempt altogether. Everything else is identical to a K1EL — same
settings panel, same protocol.
QSL_VIA is the manager. QSL_SENT_VIA and QSL_RCVD_VIA are the ADIF "QSL Via"
enumeration — B bureau, D direct, E electronic, M manager (import-only) —
and say how a card travelled. OpsLog had one column for all three:
- the import folded QSL_SENT_VIA into QSL_VIA whenever QSL_VIA was empty,
which is exactly a Log4OM export (it defaults QSL_SENT_VIA to E), so
OE6CLD saw "E" everywhere OpsLog shows the manager;
- QSL_RCVD_VIA was listed in adifPromoted with no column behind it, so it
was not stored, not kept among the extras, and not exported — dropped
outright on import;
- neither was ever written on export, so an import followed by an export
destroyed both;
- and OpsLog polluted the field itself: the QSL Manager panel wrote
"Bureau" / "Direct" / "Electronic", in full words, into QSL_VIA.
Two columns added (migration 0027), carried through the five places a
promoted ADIF field has to touch, with round-trip tests pinning the reported
case. The QSL panel now offers Bureau / Direct / Electronic for each
direction and stores the enumeration; the manager field is labelled as the
manager and holds only that. M is kept when a file gives it and never
written back out.
Existing logs hold a mixture of the two in one column. The repair is offered,
not performed: the count is shown once per log with a plain question, and a
"no" is remembered. It moves only where QSL_SENT_VIA is still empty, and only
values that normalise to the enumeration — a manager is a callsign and can
never be one of those six words, which a test pins against real manager calls.
An operator asked why K1SEI showed "Middlesex" in Info (F2) and "Lower
Connecticut River Valley" in the cluster. Two sources: the entry panel has
a callbook answer, a spot carries only a callsign so the cluster derives one
from the FCC licence ZIP through GeoNames — and GeoNames has followed the
Census in replacing Connecticut's counties with the 2022 planning regions.
No award, callbook or log uses those, so every CT station matched nothing:
new county for ever, and counting toward nothing.
Measured against a full ULS import (1 556 444 US callsigns), 23 223 resolved
to a name the USA-CA reference does not contain. Three causes, three fixes:
- Spelling. "City and County of San Francisco", "Baltimore (city)",
"Nome (CA)", plus counties renamed since the award list was drawn
(Kusilvak, Oglala Lakota, the Valdez-Cordova split) and Alaska's four
"X City and Borough", whose reference codes read "JUNEAUCITYAND" because
the county-type suffix strip eats the wrong end. Normalised in
award.USCountyKey, which both sides already go through. 7 515 callsigns,
no re-download needed.
- Doña Ana, NM shipped into the reference as "NM/DO̱AANA" — mangled by a
non-UTF-8 CSV line, a code nothing could ever produce, so that county was
unwinnable and silent about it. Row repaired, cntygen now refuses such a
line, and a test makes every one of the 3 102 references reproduce its own
code from its own name.
- Connecticut. A planning region is drawn from towns in several counties, so
no name maps to a name — only the ZIP can resolve it. cmd/ctzipgen builds
the table from the Census 2020 crosswalk, filling PO-box-only ZIPs from the
nearest resolved centroid; all 11 ZIPs GeoNames still labels with a real
county agree with the result. 15 037 callsigns, applied at import, so the
store now carries a rules version and Settings says when a re-download is
needed.
Alignment itself is the last piece: a spot now shows the county the station is
logged with when we have one, and falls back to the ZIP-derived county only for
stations never worked.
The sampled colours were Warm light's own (#faf6ea / #e8dfc9 / #ddd2b8) —
the annotated screenshot was that theme, and the request written on it was
"just a little darker". Keep the cream on panels and the entry strip, take
the page, tab bar, toolbars and table headers a shade deeper, and move the
accent from burnt orange to ochre so the two are told apart in the picker.
Built from the three sands an operator sent: #faf6eb for panels, #e8dfca
for the page behind them, #ddd2ba for toolbars, table headers and rows.
The ordering is what makes it work — a panel reads as lifted off the page
and the log grid as settled into it, so rows stay scannable without extra
rules. Ink is a deep warm brown; pure black on sand glares.
A second profile is usually the same operator with a different rig or a
different locator — same callsign, same cards. Having to redraw a design
because the antenna changed is work nobody should do.
The designer now lists the designs the active profile cannot see and copies a
chosen one into it. Designs it already sees — its own, and the shared ones —
are left out: they are not something to copy.
A COPY, not a move or a share. The original profile keeps its design untouched
and the duplicate is free to diverge, which it usually will: a second profile
exists because something differs, and that something often ends up on the card.
The PICTURES are copied too, and that is the part worth getting right. Stored
documents reference photos by name relative to the template's own asset folder,
so duplicating the JSON alone would point the new design at files that are not
in its folder. It is validated against its own folder afterwards, and a failure
rolls the row back rather than leaving a design whose pictures are missing.
Sharing the source's folder was the other option and a worse one: deleting
either design would then have emptied the other.
The first version was a single switch meaning "command them all", and that is
wrong the moment a station has three: two SPE on a combiner and a PowerGenius
on another antenna would all go into OPERATE together, keying an amplifier that
has nothing to do with the pair.
It is now a set. Each amplifier is ticked into the group or not, the group is
stored as a list of ids, and an amplifier outside it keeps its own buttons —
which is the entire point of it being a set.
A group of fewer than two members is stored as none: one amplifier coupled to
itself would make every command fan out to a single member for ever.
A remembered member that is no longer running is skipped rather than failing
the command — deleting one amplifier must not break the button on the other.
An amplifier saved without an id cannot join, and the panel says so instead of
quietly omitting it from the list.
It sat above the first amplifier card. With three cards configured — the case
it exists for — that is a scroll away from anything the operator is looking at,
and it was reported as missing rather than misplaced.
Moved next to Add amplifier: coupling belongs to the SET of amplifiers, not to
any one of them, so it belongs with the other set-level control.
The SPE CO1-2 combiner is an RF device: it sums two amplifiers and commands
nothing. So "combined" operation is really two amplifiers that must be held in
the same state, and one left in STANDBY while the other keys means the combiner
sees power on a single input.
A switch in Settings → Amplifier makes ON, OFF and OPERATE act on every
configured amplifier. Offered only with two or more: coupling one amplifier to
itself is a switch that cannot do anything.
The METERS stay per amplifier, deliberately. Two amps combined are still two
amps, and an operator watching for one of them to run away needs to see them
apart — a summed bar would hide exactly the fault worth catching.
Fanned out in AmpOperate/AmpPower rather than in the UI: the card and the docked
widget both call these, and a coupling built into one would be missing from the
other, which on a combiner means one amplifier keyed and one not. The clicked
amplifier goes first, so a partial failure still did what the operator asked
before it stopped.
While linked, an amplifier with no power command — a PGXL on its direct link —
is skipped silently rather than reported: it would make a successful pair look
broken.
Puts "F4BPO is on air 14,074,000 FT8 IC-7300" on hrdlog.net's front page while
the station is operating, which is what HRDLog's own "Automatic HRDLog ON AIR"
setting does.
The endpoint and its field names come from HRDLog's own library
(github.com/iw1qlh/HRDLOG-net-library, HrdProtocol.SendOnAirAsync): OnAir.aspx,
with Frequency in Hz, Mode, Radio, Callsign, Code and App. Read rather than
guessed — an invented endpoint would have produced a switch that silently did
nothing.
HTTPS where that library uses plain HTTP: the upload code is a credential and
has no business crossing the network in clear, and the sibling NewEntry
endpoint on the same host already serves TLS.
A heartbeat every two minutes, not a change notification — HRDLog drops a
station from the list when it stops hearing from it. Silent when switched off,
unconfigured, or when the rig reports no frequency: announcing 0 Hz would say
the operator is on air on nothing. Failures are logged, never toasted; a
broadcast the operator did not ask for at that instant must not interrupt them
every two minutes on a flaky link.
Its own switch beside auto-upload rather than folded into it: this is a live
status and needs the rig readable, not a QSO.
compactH was 158px, "tuned so the compact entry strip fits in a single row".
A constant tuned against a layout stops being true the moment the layout
changes, and this one outlived a strip that had since shrunk — leaving about
70px of empty window under the fields.
The frontend now measures what it rendered and asks for that height, watched by
a ResizeObserver so a strip that wraps at a narrow width is followed too. The
topbar is added as its declared h-8 rather than measured, since it is fixed.
Bounded in the backend: a measurement of zero — a layout not yet painted —
must not collapse the window, and the call is ignored unless compact is on so
nothing can shrink the normal window. Rounded to whole pixels so a sub-pixel
reflow cannot start a resize loop.
It went under the Station Control rotator; the compass that wanted it is the
docked one beside the entry strip. Both are the same RotorCompass, so the
readout moves INTO that component: every compass in the app carries it, and no
caller draws its own.
The bezel already showed the short path as a red marker, but a marker is a
direction, not a number — and the numbers in the status bar are 10px, which is
what prompted this.
Clickable only when the caller passed onGoto, since a compass rendered without
one cannot turn anything and a button that does nothing is worse than a label.
The same pair already sits in the status bar, where it is 10px and several
operators reported not being able to read it. Repeated under the compass at a
size that can be read across a shack.
Clickable, like the ones in the status bar: a heading you can see and not act
on would be a step backwards from what is already there. Disabled and dashed
when no station is entered, rather than showing a heading to nowhere.
The same answer the Details tab already gave, moved to where the county is now
typed — a badge in a tab nobody has open while working a station is a badge
that does not do its job.
Debounced at 300 ms and keyed on state + county together: the field is typed
into as well as filled by the lookup, and the check queries the log. A county
name means nothing without its state, so both have to settle before asking.