rouggy e0b110392a fix(update): wait for the old process, not for a fixed window
The relaunch after an update stopped working, and the regression is mine:
removing the PowerShell helper — which is what Defender was reading as a
dropper — also removed the wait it was doing. Nothing took over the job.

The numbers made it certain rather than unlucky. The instance being
replaced is allowed THIRTY seconds to shut down (armExitWatchdog forces
it out at that point) because it closes a remote logbook, a CAT session
and sometimes a backup. The new instance was patient with the
single-instance mutex for TWENTY. On any station where shutting down ran
past that, the new process gave up and exited in silence: no window after
an update, and the previous OpsLog still in the task manager. Exactly the
report.

Both relaunch paths now pass --wait-pid, and the new process waits on
that process's handle — a plain kernel wait, which ends the instant the
old one ends, however long or short that is, and looks nothing like a
script starting another program. The mutex retry stays as a backstop and
goes to forty-five seconds, so it is longer than the wait it exists for
rather than shorter.

And when the old process really has not gone, the message says that
instead of "OpsLog is already running" — after an update the operator did
not start a second copy, and what they need to know is which one to
close.

A test keeps the two spawn sites honest: a relaunch added without
--wait-pid is this bug again.
2026-09-08 09:18:06 +02:00
rouggy 0430aab78e fix(update): relaunch without a hidden PowerShell
Windows Defender removed 0.27.14 from a station as
Trojan:Script/Wacatac.H!ml. That detection is machine-learning, not a
signature, and the behaviour it scored is ours: an unsigned binary
replaces itself on disk, clears the mark-of-the-web, and spawns a
windowless PowerShell that waits for its own process to die before
starting another executable. Byte for byte, that is a dropper; the model
reads the shape, not the intention, and "Script/" names the PowerShell.

The wait it was written for is not needed. --post-update already makes
the new instance patient with the single-instance mutex — twenty seconds
of it — so the new exe can be started directly while this one is still
shutting down and simply wait its turn.

The deferred-swap fallback keeps its helper: nothing else on a stock
Windows can wait for a pid and then move a file over an image that is
still running. It is reached only when the rename failed, never on the
ordinary path.
2026-09-07 09:36:02 +02:00
rouggy c0dc1bfcc4 feat(qsl): credit line at the foot of the default QSL e-mail
"Designed & sent by OpsLog — https://github.com/GregTroar/OpsLog/releases/latest"
now closes the default body, so a fresh install sends it without being asked.

Put in the TEMPLATE, not appended at send time. Two consequences, both of them
the point: an operator who does not want it deletes the line once and it is
gone, and one who has already written their own body never sees it appear —
a stored template is returned verbatim and the default is only the fallback.
Appending it at send would have made it unremovable, which is not a thing to do
to somebody's outgoing mail.

The link is the human release page. updateCheckURL sits next to it in update.go
and answers JSON, which is the easy mistake here — a correspondent who clicks
the credit gets a download page, and a test says so.
2026-08-16 11:07:06 +02:00
rouggy 17819ea673 fix(update): survive an exe that cannot be renamed
Several operators hit "stage current exe: rename …\OpsLog.exe …\OpsLog.exe.old:
Accès refusé" and could not update again. Two separate causes, both ours to
handle.

The staging name was fixed. os.Rename replaces its target, so a single leftover
".old" that could not be deleted — a scanner holding it open is the usual
reason, and the pre-existing os.Remove was best-effort and ignored — made every
later update fail with that error, permanently, recoverable only by deleting the
file by hand. Staging now uses a unique ".old-<nanos>", which no leftover can
block, and the startup cleanup sweeps the pattern instead of one name.

Renaming a running image is legal on Windows, but some endpoint protection
(Bitdefender's ransomware remediation among them) blocks it outright, and no
retry gets past that. So the swap is deferred: the new build is parked beside
the old one and a detached helper moves it into place after this process exits,
when the file is no longer a running image. It keeps trying for ten seconds,
since a scanner tends to let go a beat after the process dies.

A short retry stays in front of both, for the ordinary case of a scanner holding
the file it has just watched being written.

If even the deferred move fails, OpsLog restarts on the CURRENT version rather
than leaving the operator with nothing — someone mid-QSO losing their logger is
worse than an update that waits — and only a successful swap passes
--post-update, so the download survives for the next attempt instead of being
swept by the cleanup.
2026-08-09 15:38:50 +02:00
rouggy d327db3f57 fix: auto-update relaunch — clear Mark-of-the-Web + wait for exit
The new build downloaded and OpsLog quit, but never came back. Two Windows
causes: the freshly written exe carried the internet Zone.Identifier mark, so
SmartScreen wanted to prompt "are you sure you want to open this?" — invisibly,
since we launch it programmatically — and silently blocked the launch; and
starting the new exe while the old one was still exiting raced the single-
instance mutex.

Now the swapped exe's Zone.Identifier stream is removed, and the relaunch is
done by a detached, hidden PowerShell that Wait-Process's on our PID (so we're
fully gone and the mutex is free) before Start-Process'ing the new exe.
2026-07-19 19:53:19 +02:00
rouggy 5d0906f00e feat: in-app auto-updater — download, swap and relaunch
CheckForUpdate now also resolves the release's downloadable asset (portable
.exe, or a .zip to unpack). DownloadAndApplyUpdate streams it with progress
events (update:progress 0-100), swaps it in for the running exe (rename the
current one to .old — allowed for a running image on Windows — move the new one
into place, roll back on failure), then relaunches with --post-update and quits.

main: a --post-update relaunch retries the single-instance mutex for ~20 s so
the fresh process waits for the old one to exit and free it, then clears the
.old exe left behind. Falls back to opening the release page when a release has
no auto-download asset.
2026-07-19 18:14:56 +02:00
rouggy 957182611d feat: check for available updates 2026-06-16 19:52:23 +02:00