The data folder is created and stays empty, the process keeps running, and no window appears. Nothing returns, so nothing is logged: WebView2 never hands control back, and a hang has no error to report. So the ABSENCE of progress is reported. If OnStartup has not been reached twelve seconds after wails.Run, that is written to the startup log and shown in a message box naming the two causes — a missing WebView2 runtime and an antivirus blocking msedgewebview2.exe — because 'OpsLog is not responding' otherwise sends people to reinstall OpsLog, which is the one thing that cannot help: the part that has not started is not ours.
209 lines
8.3 KiB
Go
209 lines
8.3 KiB
Go
package main
|
|
|
|
import (
|
|
"embed"
|
|
"os"
|
|
"strings"
|
|
"time"
|
|
|
|
"github.com/wailsapp/wails/v2"
|
|
"github.com/wailsapp/wails/v2/pkg/options"
|
|
"github.com/wailsapp/wails/v2/pkg/options/assetserver"
|
|
)
|
|
|
|
//go:embed all:frontend/dist
|
|
var assets embed.FS
|
|
|
|
// profileArg extracts a profile name from the command line. Accepts
|
|
// "--profile NAME", "--profile=NAME", "-profile NAME", "-p NAME" so a desktop
|
|
// shortcut can launch OpsLog straight into a given profile (e.g. F4BPO / TM2Q).
|
|
func profileArg(args []string) string {
|
|
for i := 0; i < len(args); i++ {
|
|
a := args[i]
|
|
switch {
|
|
case a == "--profile" || a == "-profile" || a == "-p":
|
|
if i+1 < len(args) {
|
|
return strings.TrimSpace(args[i+1])
|
|
}
|
|
case strings.HasPrefix(a, "--profile="):
|
|
return strings.TrimSpace(strings.TrimPrefix(a, "--profile="))
|
|
case strings.HasPrefix(a, "-profile="):
|
|
return strings.TrimSpace(strings.TrimPrefix(a, "-profile="))
|
|
case strings.HasPrefix(a, "-p="):
|
|
return strings.TrimSpace(strings.TrimPrefix(a, "-p="))
|
|
}
|
|
}
|
|
return ""
|
|
}
|
|
|
|
// hasFlag reports whether flag is present in args.
|
|
func hasFlag(args []string, flag string) bool {
|
|
for _, a := range args {
|
|
if a == flag {
|
|
return true
|
|
}
|
|
}
|
|
return false
|
|
}
|
|
|
|
// acquireInstance grabs the single-instance mutex. On a normal launch it's a plain
|
|
// try (fail → another OpsLog is running, so exit). On a --post-update relaunch the
|
|
// previous instance may still be shutting down and holding the mutex, so retry for
|
|
// a few seconds until it frees.
|
|
func acquireInstance(postUpdate bool) bool {
|
|
if acquireSingleInstance() {
|
|
return true
|
|
}
|
|
if !postUpdate {
|
|
return false
|
|
}
|
|
deadline := time.Now().Add(20 * time.Second)
|
|
for time.Now().Before(deadline) {
|
|
time.Sleep(300 * time.Millisecond)
|
|
if acquireSingleInstance() {
|
|
return true
|
|
}
|
|
}
|
|
return false
|
|
}
|
|
|
|
// processStart is stamped on the very first instruction of main, before the
|
|
// single-instance guard and before anything else runs.
|
|
//
|
|
// It exists to split a slow launch in two, because the log alone could not: the
|
|
// first line applog writes already sits inside startup(), so everything spent
|
|
// loading the binary and creating the WebView2 environment happened before the
|
|
// log begins and was invisible. An operator reporting "nothing happens for three
|
|
// seconds" was impossible to answer from a file whose first timestamp is the
|
|
// moment the app was already running.
|
|
var processStart = time.Now()
|
|
|
|
func main() {
|
|
// Single-instance guard: if OpsLog is already running, focus that window and
|
|
// exit instead of spawning a duplicate. A second process would open its own
|
|
// CAT (FlexRadio) connection and Ultrabeam follow loop, and the two would
|
|
// fight over the rig/antenna frequency — the cause of "the antenna re-tunes on
|
|
// its own" when a windowless zombie instance was left running.
|
|
// A --post-update relaunch (from the auto-updater) may start while the previous
|
|
// instance is still exiting and holding the single-instance mutex — wait for it
|
|
// to free instead of bailing out. Then clear the old exe it left behind.
|
|
bootLogLaunch()
|
|
postUpdate := hasFlag(os.Args[1:], "--post-update")
|
|
if !acquireInstance(postUpdate) {
|
|
// SAID, not merely done. This exit is correct — a second instance would
|
|
// fight the first over the rig — but it happened in total silence: no
|
|
// window, no data folder, no log, which is indistinguishable from a
|
|
// program that died on its first instruction.
|
|
bootLog("another instance already holds the single-instance mutex - exiting")
|
|
fatalBox("OpsLog", "OpsLog is already running.\n\nLook for its window, or for a leftover OpsLog.exe in the Task Manager, and close it before starting another.")
|
|
return
|
|
}
|
|
bootLog("single-instance mutex acquired")
|
|
|
|
// The data folder is created BESIDE the executable, so a copy dropped into
|
|
// Program Files is refused the write by Windows — and that refusal ended the
|
|
// launch with nothing on screen and nothing in any file, since the only log
|
|
// OpsLog had was inside the folder it could not create.
|
|
if err := checkDataDirWritable(); err != nil {
|
|
bootLog("FATAL %v", err)
|
|
fatalBox("OpsLog", "OpsLog cannot write next to its own program file.\n\n"+err.Error()+
|
|
"\n\nMove OpsLog.exe somewhere your account can write — a folder in Documents, or the desktop — and start it again. Program Files is refused to anything not running as administrator.")
|
|
return
|
|
}
|
|
if postUpdate {
|
|
cleanupOldUpdateBinary()
|
|
}
|
|
|
|
// The WebView2 runtime, named before the window is attempted. Its absence is
|
|
// the classic silent failure — the process starts, the browser environment
|
|
// cannot be created, and on some machines that ends the launch without an
|
|
// error anyone can see.
|
|
if v := webView2Version(); v != "" {
|
|
bootLog("WebView2 runtime: %s", v)
|
|
} else {
|
|
bootLog("WebView2 runtime: NOT FOUND — install Microsoft Edge WebView2 Runtime")
|
|
}
|
|
|
|
// Create an instance of the app structure
|
|
app := NewApp()
|
|
app.startupProfile = profileArg(os.Args[1:])
|
|
|
|
// Restore the window's SIZE and maximised state at CREATION, from the geometry
|
|
// saved on last close. Doing it here (not after startup) is what makes the
|
|
// window open already at the right size instead of maximising then snapping
|
|
// smaller. Position can't be set through options, so it is applied while the
|
|
// window is still hidden (domReady) — invisible, so no jump. First run, or a
|
|
// window closed maximised, keeps the historical maximised default.
|
|
width, height := 1400, 900
|
|
startState := options.Maximised
|
|
if dataDir, err := userDataDir(); err == nil {
|
|
if ws, ok := readWindowState(dataDir); ok && !ws.Maximised &&
|
|
ws.Width >= 1100 && ws.Height >= 700 && ws.Width <= 8000 && ws.Height <= 6000 {
|
|
width, height = ws.Width, ws.Height
|
|
startState = options.Normal
|
|
}
|
|
}
|
|
|
|
// Create application with options
|
|
// A HANG has no error to report, and that is the shape being chased here:
|
|
// the process stays up, the data folder is created and stays empty, and no
|
|
// window appears — WebView2 never finishes creating its environment, and
|
|
// nothing returns to be logged.
|
|
//
|
|
// So the absence of progress is what gets reported. If OnStartup has not
|
|
// been reached a few seconds in, this says so and names the two things that
|
|
// cause it, rather than leaving an operator watching a process that is doing
|
|
// nothing at all.
|
|
go func() {
|
|
time.Sleep(12 * time.Second)
|
|
if startupReached.Load() {
|
|
return
|
|
}
|
|
bootLog("STUCK: 12 s after wails.Run and the window has not started — WebView2 never handed control back")
|
|
fatalBox("OpsLog", startupStuckMessage)
|
|
}()
|
|
bootLog("entering wails.Run (window %dx%d, state %v)", width, height, startState)
|
|
err := wails.Run(&options.App{
|
|
Title: "OpsLog",
|
|
Width: width,
|
|
Height: height,
|
|
MinWidth: 1100,
|
|
MinHeight: 700,
|
|
WindowStartState: startState,
|
|
// No OS title bar: it was a dead 32-pixel band above a window that already
|
|
// has its own title strip. The app header takes over — it carries the drag
|
|
// region, the double-click-to-maximise, and the minimise/maximise/close
|
|
// buttons. Windows still draws the resize borders and honours Aero Snap,
|
|
// which is why the frame is dropped rather than the whole chrome.
|
|
Frameless: true,
|
|
// Start hidden and reveal only once the saved position has been applied and
|
|
// the DOM has painted (OnDomReady → domReady) — so the window appears
|
|
// already at its final size and position, with no post-launch jump.
|
|
StartHidden: true,
|
|
AssetServer: &assetserver.Options{
|
|
Assets: assets,
|
|
},
|
|
// The colour the window is painted before the WebView draws. Matches the
|
|
// graphite theme's background (#16181d), which is the default on a fresh
|
|
// install — otherwise every launch flashes white first.
|
|
BackgroundColour: &options.RGBA{R: 0x16, G: 0x18, B: 0x1d, A: 1},
|
|
OnStartup: app.startup,
|
|
OnDomReady: app.domReady,
|
|
OnBeforeClose: app.beforeClose,
|
|
OnShutdown: app.shutdown,
|
|
Bind: []interface{}{
|
|
app,
|
|
},
|
|
})
|
|
|
|
bootLog("wails.Run returned")
|
|
if err != nil {
|
|
// The last thing that can fail before a window exists, and the most
|
|
// opaque of them: a missing WebView2 runtime lands here. println goes
|
|
// nowhere in a GUI-subsystem program, so this went unseen and unlogged.
|
|
bootLog("FATAL wails.Run: %v", err)
|
|
fatalBox("OpsLog", "OpsLog could not open its window.\n\n"+err.Error()+
|
|
"\n\nThis is usually a missing WebView2 runtime — install \"Microsoft Edge WebView2 Runtime\" and try again.")
|
|
}
|
|
}
|