355 Commits
Author SHA1 Message Date
rouggy bde136b98b fix(pgxl): match a reply to the command that asked for it
The amplifier PUSHES status frames ("S0|state=…") on the same socket it answers
commands on, and it pushes them constantly once in OPERATE - power, SWR and
temperature all move while transmitting.

command() read exactly one line and took whatever arrived first as its answer.
One pushed frame therefore put the stream permanently one reply behind: every
later command read the PREVIOUS command's answer, and eventually one waited out
the 3 s deadline, failed, and dropped the connection. Hence a fresh TCP
connection and a fresh authentication every few seconds in the log.

The stall in transmit is the same defect seen from the other side: command()
holds the connection mutex across that whole dead wait, so SetOperate and every
other control queued behind up to three seconds of nothing.

It only appeared remotely and in OPERATE because that is when there is anything
to push - on a LAN with an idle amplifier the race hardly ever opens. Which is
why it did not do this yesterday.

readReplyLocked now reads until the R<id>| that belongs to the command, feeding
every frame it passes to parse() on the way - a pushed status is fresher than
the one we were about to ask for, so nothing is wasted.

authLocked used the same one-line read and worked around this by re-sending the
whole handshake, which is visible in the log as "auth reply=S0|state=IDLE
(try 1)" followed by a second attempt. It goes through the same reader now.
2026-08-10 19:45:54 +02:00
rouggy ae7472a67d feat(station): MY_IOTA in the station profile
IOTA is an official ADIF field, and almost everything for it was already here:
the qso table has carried my_iota since the first migration, the insert and scan
handle it, and both ADIF import and export write it. The one missing link was
the station profile, so the reference had to be typed on every contact of an
island activation, or added afterwards in a bulk edit.

Migration 0025 adds the column; it joins my_sota_ref and my_pota_ref in the
profile, in the Station Information panel, and in the same stamp-if-empty block
that fills the other My* fields on a logged QSO.

Uppercased and trimmed on save. ADIF spells it EU-005, and an operator typing
"eu-005" would otherwise put a reference no award matcher recognises on every
QSO of an activation - the kind of mistake you only find months later.
2026-08-10 19:28:07 +02:00
rouggy 0d48dbfd17 fix(cluster): drop the worked index when a QSO is logged
AddQSO emitted qso:logged but never invalidated the cluster status snapshot.
The frontend did its part - it re-queried every visible spot two seconds later -
and ClusterSpotStatuses answered out of a snapshot built before the contact, so
it returned exactly the same "new band" as before. For ever, until an import, an
edit or a profile switch happened to invalidate it for another reason.

Reported twice: an E51 and then a ZD7 that stayed yellow on the band map with
the QSO plainly in the log. The first report was answered by fixing the
visibility gate, which was a real bug of its own and hid this one.

Confirmed against the operator's MySQL logbook rather than guessed: ZD7BG has
dxcc=250 on all eleven QSOs and 0 of 29579 rows lack a DXCC number, which ruled
out the missing-entity-number theory and pointed here.

Deliberately not invalidateAwardStats(): that also drops the award matrices,
which are expensive on a large log, and a contest run would pay for it once per
QSO. This index is a few DISTINCT scans and it is what the spot colours read.

Also fixes the new worked-grid query, which asked for a column named
"gridsquare". The column is "grid" - gridsquare_ext is a different one - so NEW
GRID could never have worked on either backend. Verified against the real
database: 12516 distinct grid|mode pairs.
2026-08-10 19:18:49 +02:00
rouggy 9b2115be8f feat(cluster): grids from the UDP decodes, plus spotter continent and LoTW
Backend groundwork; the columns and filters that consume it come next.

GRIDS. A CQ is the one WSJT-X message that carries a locator, and wsjtSender was
throwing that token away. It is now returned, validated as a real field+square,
and remembered per callsign. This is the ONLY grid source available: a DX-cluster
line carries the spotter's grid at best and never the DX's, and a per-callsign
QRZ lookup under an RBN firehose is not a trade worth making. So grids are known
for the stations this receiver decoded - which is exactly the FT8/FT4 watering
hole an operator is looking at while grid chasing.

RR73 is why the grid is validated rather than pattern-matched. R is inside A-R
and 73 inside 00-99, so a sign-off satisfies the Maidenhead shape exactly and
would have planted a grid that does not exist into the index, silently.

NEW GRID keys on "GRID|MODE" with the mode put through the same normMode as
everything else, so the "group digital modes" option decides whether a grid
worked on FT8 is still new on FT4 - one rule, no branch. Grids are truncated to
four characters: a log holds a mix of JN36 and JN36QU, and without that the same
square is new forever, once per subsquare.

On cost, which was the condition: one more DISTINCT scan when the status
snapshot is rebuilt, then map lookups per spot. The same shape as the county and
POTA sets it sits beside, and the snapshot exists precisely so a spot batch never
touches the logbook.

Spotter continent and the LoTW flag come from tables already in memory - the
DXCC prefix table and ARRL's user list - so they cost a lookup each. The spotter
continent answers a different question from the DX's: whether anyone near you is
hearing this at all.
2026-08-10 16:52:36 +02:00
rouggy 9f62808392 fix(webpub): the published page could not sort a date, and could not be unsorted
parseFloat accepts a numeric PREFIX. "2026-08-10" therefore became the number
2026, every date in the same year compared equal, and since the sort is stable
nothing moved: the Date column looked as though it were simply not sortable.
The same trap caught every callsign starting with a digit - 8B81SU and 8P9AB
both read as 8 - and the times, where "09:56" became 9. The numeric test is now
anchored to the whole cell, so anything that is not entirely a number is
compared as text, which is exactly right for an ISO date.

Sorting had no way back either. Each row now carries the index it was published
at, and a third click on a header restores that order. Headers also show an
arrow: with no indicator, a column that silently refused to sort was
indistinguishable from one that had sorted into the same order.

Blank cells sink in both directions rather than leading the ascending sort. An
empty field is missing data, not the smallest value.

Tested where it can be: the page ships its own script, so a regression is silent
- the table still renders, it just sorts wrongly.
2026-08-10 13:52:13 +02:00
rouggy f6f5235a8b feat(bandopen): announce sporadic-E openings on 6, 4 and 2 m
Observation, not prediction, and it needs no new data source: the cluster event
worker already enriches every spot with the great-circle distance and bearing
from the operator's grid, which is exactly what a single-hop Es detection rests
on.

The signature is four or more DISTINCT stations at 500-2400 km inside a 90
degree bearing sector within twelve minutes. Each constraint earns its place:
distinct callsigns because one station spotted by six skimmers is six spots and
one station; the lower bound because a 6 m contact under 500 km is ordinary
tropo and says nothing about the ionosphere; the upper bound because past one
hop the bearing test stops meaning anything; and the sector because a real Es
cloud illuminates a direction, which is what separates an opening from a merely
busy evening.

Fed AFTER the Historical guard in the worker. A SH/DX reply replays a hundred
past spots in a second - precisely the shape of a burst - and would announce an
opening that ended hours ago.

Season LABELS, it never gates. Both hemispheres get a summer peak and a lesser
winter one, and an opening outside those is announced with "unusual for the
season" attached: the rare one is the one an operator must not hear about last.

One announcement per band per opening (45 minute quiet period). An opening runs
for hours and produces hundreds of spots; one alert is information, forty is
noise.
2026-08-10 09:49:22 +02:00
rouggy fb78b1c052 feat(webpublish): publish the log as a web page or CSV, with FTP upload
Settings -> Web publishing. Renders the last N QSOs with the columns the
operator picks, writes the file locally, and optionally uploads it by FTP or
explicit FTPS.

Local write FIRST, upload second, always. A network failure then leaves a good
file on disk that can be published another way, instead of a truncated one on
the server. The local write itself goes to a temp file and renames over the
target, so a reader — or a syncing client — never sees a half-written page.

The HTML page is fully self-contained: inline CSS, inline sort script, no font,
no CDN, no external request at all. It has to work on hosting that blocks
third-party requests, and a page about someone's hobby should not report its
readers to anyone.

Columns are a curated set, not "every ADIF field". This is published to the
public: RST and QSL status belong on it, the operator's home address does not.

Two triggers, both debounced through one path: a QSO is logged, or the optional
timer fires. Fifteen seconds of coalescing means a run of contacts produces one
upload rather than one per QSO, and nobody reading a web page can tell the
difference.

The config is one JSON blob under a single settings key, and that key is marked
sensitive: the FTP password lives inside it, so the whole blob is encrypted at
rest with the others. A locked vault reads back empty, which correctly reads as
"not configured" — publishing must not run with a password it cannot decrypt.
2026-08-10 09:07:08 +02:00
rouggy 79427ccd18 fix(awards): apply the reference Prefix where it can actually help
Prefix exists so a field holding a bare value counts for an award whose codes
carry a letter: a French operator writes "74" in STATE, DDFM's codes are "D74".
Def's own doc says exactly that. But searchOne applied the prefix AFTER looking
the token up in the reference list — after the step that had just failed — so
the bare form matched nothing and the prefix decorated an empty result. The only
way through was a regex, in a mode where the operator had chosen "code" and
explicitly not "pattern".

The token lookup now tries the prefixed form when the bare one is not a known
reference. The list stays the authority: an unknown number still matches
nothing, so the prefix completes references rather than inventing them.

Second bug in the same pass: the blanket prefix also hit codes that came
straight OUT of the list, so a field already holding "D74" produced "DD74" as
soon as a prefix was configured — for both the token lookup and the
description matcher. Branches that yield whole codes are now excluded from it;
the ones that yield a raw capture (regex, whole-field split) still get it.
2026-08-09 09:43:27 +02:00
rouggy 4352b9aec5 fix(udp): read WSJT-X packets that arrive through a relay
A forwarder (W&P, seen in the field in front of MSHV) prepends the origin as
plain text before re-broadcasting:

    "127.0.0.1:2237|" + <the original, untouched WSJT-X packet>

That puts the magic 15 bytes in, so every datagram failed on "bad magic
0x3132372e" — those four bytes being ASCII "127." — and an operator running
MSHV behind the relay saw no decodes, no callsigns and no auto-logged QSOs.

No new service type: what follows the header IS a WSJT-X packet, so the parser
and everything downstream apply unchanged, and a separate type would duplicate
decode, status and logged-ADIF handling to strip 15 bytes. ParseWSJT skips the
header instead, which also covers any other relay that wraps traffic this way.

The match is deliberately narrow — the magic must fall within the first 64
bytes AND every byte before it must be printable ASCII. A corrupt or truncated
packet that merely contains those four bytes somewhere is not resurrected into
a QSO; it fails exactly as it did before.

Test data is the real captured datagram, header included.
2026-08-09 08:06:21 +02:00
rouggy a0f7f2abf0 feat(udp): show the packet behind a parse error, and stop repeating it
"WSJT parse error: bad magic 0x3132372e" named neither the sender nor the
payload, so there was nothing to act on — even though those four bytes are
ASCII "127.", i.e. some program broadcasting an address on a port expecting
WSJT-X binary.

The line now carries the remote address, the size, a printable preview and a
hex dump of the first 96 bytes. Text senders are readable at a glance; a
genuinely binary payload still shows its bytes.

And it stops after five. The reported case wrote that line about 150 times a
second: a permanently misconfigured port would fill the 10 MB rotating log with
one repeated sentence and bury every other piece of evidence — the log's whole
purpose. The fifth line names the two things worth checking, the sender and the
service type.

N1MM's parse error goes through the same path; it had no packet detail either.
2026-08-09 07:59:51 +02:00
rouggy 40f5960c76 feat(awards): implement the QRZ.com and Custom confirmation sources
The award editor offered five confirmation sources and Def's own doc comment
named five, but confirmed() had cases for three. "qrzcom" and "custom" fell
through the switch, so ticking either marked nothing as confirmed — the exact
failure the GrantCodes comment in this struct warns about: a checkbox that does
nothing is worse than no checkbox, because it is trusted.

QRZ.com reads qrzcom_qso_download_status, not the upload one: uploading a QSO
is us telling QRZ about it, which confirms nothing.

Custom names a field. Rather than a checkbox per external source, the Def gains
ConfirmField + ConfirmValue: any QSO field or ADIF extras key, and optionally
the comma-separated values that count. That one shape covers the three cases
asked for — the OpsLog card marker (APP_OPSLOG_QSL_RCVD), an arbitrary ADIF
tag, and a tag stamped by an imported club list — because all three end up as a
field on the QSO.

An empty ConfirmValue means any non-empty content confirms: the OpsLog marker
stores the date the card arrived, not a Y/N flag. A custom source naming NO
field confirms nothing, deliberately — the opposite default would silently mark
a whole logbook confirmed.
2026-08-09 02:11:24 +02:00
rouggy 59135d55ab fix(window): don't save the geometry of a minimised window
Windows parks a minimised window at -32000,-32000 with a stub size and reports
it as not-maximised, so closing OpsLog from the taskbar while minimised stored
exactly that. Seen in a log: "window: saving -32000,-32000 237x39
maximised=false".

The restore side already rejects both the impossible corner and the
below-minimum size, so nothing opened off-screen — but it fell back to the
default placement, and the operator silently lost the size, the position and the
maximised state they had set.

saveWindowState now keeps what was already stored when the window is minimised.
Two tests for that: the Wails flag, and the -32000 corner, because a window that
is mid-close can sit at that corner with the flag already cleared. A poisoned
window.json repairs itself on the next close of an on-screen window.
2026-08-09 01:47:45 +02:00
rouggy 642ed358c2 feat(worked): fold portable callsigns into the worked-before history
Typing RK3DWA found nothing while RK3DWA/3 found 21 QSOs, so a station's
history was only visible if you happened to type the exact form it had been
logged under — and an operator who worked it as /0, /P or /MM saw none of it.
The other RDA tools and Log4OM fold these together; this does too.

The predicate strips the suffix from what was typed and matches "call = base OR
call LIKE base/%", so it works from either end: the base call finds the portable
QSOs and a portable call finds the plain ones. Deliberately not a bare prefix
LIKE 'RK3DWA%', which would also match RK3DWAB — a different station. The '/' is
what makes it the same operator.

Settings -> General to turn it off. Default ON, hence the inverted storage: an
existing install has no key, and reading that as OFF would leave everyone with
the behaviour we were asked to change.

Contest dupe checking is untouched — it runs through ContestDupe, a separate
binding, and stays an exact match as a contest requires.
2026-08-08 23:24:23 +02:00
rouggy 90c6458af0 fix(rigctld): never leave the rig keyed when the client goes away
The Kenwood/Elecraft backend deliberately suspends its wire poll while PTT is
held — a K3 answers "?;" to IF; during transmit, and treating that as a fault
used to drop the whole CAT link. The consequence was that nothing watched the
transmitter: a client that crashed, was closed, or simply had its socket shut
under it left the rig on air.

And shutting the socket is routine. reloadCATShare tears the sharing server
down and rebuilds it on every settings save, so a Save while WSJT-X held PTT
was enough. A K3 operator's log shows exactly that: "TX;" at 17:53:09, no "RX;"
ever, the poll silent, and the rig still keyed 29 s later when the CAT link
happened to be rebuilt.

The server now drops PTT when a connection ends and when Stop() is called.
Stop() runs before reloadCAT restarts the backend, so the unkey still reaches
the radio. An atomic Swap keeps it once-only across the two paths.
2026-08-08 20:19:00 +02:00
rouggy 18f44a5aa3 fix(cat): read MD6 back as DATA on an Elecraft, not RTTY
MD6 is FSK on a Kenwood and DATA on a K3/K4. kenwoodModeToADIF decoded the
digit unconditionally as RTTY, so OpsLog contradicted the mode it had just
set: SetMode writes MD6 for a digital mode on an Elecraft, then ReadState
parsed the IF frame back as RTTY.

A K3 running FT8 therefore showed RTTY in the status bar, logged its QSOs on
RTTY, and — through the shared CAT server — told WSJT-X/JTDX the rig sat in
RTTY while they had just asked for a data mode. Found in a K3 operator's log:
every cat:state line read mode=RTTY on 21.074 FT8, two lines after OpsLog's
own "MD6;".

The digit now resolves to the configured digital mode whenever MD6 means DATA
on this rig — the Elecraft backend, and the "DATA A - MD6" data-mode option
that exists for it. A plain Kenwood still reads MD6 as RTTY.
2026-08-08 20:13:45 +02:00
rouggy 9c757e5175 feat(cat): distinct Elecraft K3/K4 backend in the rig list
The Elecraft handling was buried in the Kenwood "data mode" option, so users
couldn't find it. Add "Elecraft K3/K4" as its own entry in the CAT backend
selector. It reuses the Kenwood-dialect transport and the Kenwood USB/network
settings (the K3 emulates the Kenwood command set — a separate transport would be
a near-total duplicate), with an `elecraft` flag on the client that forces
digital modes to DATA A (MD6+DT0) — no data-mode dropdown needed. RigState still
reports Backend "kenwood" so the CW-over-CAT keyer capability keeps working.
2026-08-08 14:15:55 +02:00
rouggy 626edca8ba feat(cat): Elecraft K3/K4 DATA A — send MD6 + DT0 on data mode (from the stale branch)
Integrates the fix/jtdx-kenwood-tx work onto main: the Kenwood/Elecraft backend's
"data" data-mode path now sends MD6 then DT0 so a K3/K4 lands in DATA A — the
audio sub-mode FT8 uses. MD6 alone could leave the rig in an FSK/PSK sub-mode
where it keyed but the rear sound-card audio never modulated ("transmits but
nothing comes out"). The data-mode option is relabelled "DATA A — MD6+DT0
(Elecraft K3/K4)". A shared Kenwood/Elecraft backend is kept (the K3 emulates the
Kenwood dialect); the Elecraft specifics live behind the data-mode seam rather
than a 7000-line duplicate backend.
2026-08-07 16:37:55 +02:00
rouggy b202d98ae5 fix(awards): add a Prefix field to the primary QSOFIELDS search
Only OrRule had a Prefix ("prepended to each found reference", e.g. postal 74 →
D74); the primary search passed "" for prefix, so an award whose references are
D01/D02… couldn't prepend the D on its main rule — only on OR fallbacks. Add
Def.Prefix, pass it into the primary run(), and expose a Prefix input next to the
primary Leading/Trailing fields in the award editor.
2026-08-07 14:23:41 +02:00
rouggy 949cc17ed1 feat(backup): "keep every backup" option — timestamped files per exit
Sub-option of "back up on every exit": when on, backup.Run/RunADIF stamp the
filename with the time (opslog-YYYY-MM-DD-HHMMSS.db) so each run is a distinct
file instead of overwriting the day's snapshot. Rotation still trims to the
newest N (raise Rotation for a longer history). Threaded as a `unique` flag
through runConfiguredBackup/backupLogADIF from BackupSettings.KeepAll
(keyBackupKeepAll); UI sub-checkbox shown only when EveryExit is on.
2026-08-07 12:28:52 +02:00
rouggy 7d7d1042c0 feat(qsl): OpsLog QSL received marker + PSE/TNX card stamp + default QSL message
Received flag: new APP_OPSLOG_QSL_RCVD extra, toggled on the QSO edit window
next to QSL Message (immediate targeted write via SetOpsLogQSLReceived so it sets
AND clears reliably), plus a live PSE QSL / TNX indicator and a Recent-QSOs
column mirroring the sent one.

PSE/TNX card stamp: automatic — received → TNX, otherwise PSE QSL — exposed as
the {qso.pse_tnx} token (added to qslVars, so preview and send agree) and placed
in the default QSO-box footer; it can be moved to its own element in the designer.

Default QSL message: new qsl.default_message (QSLEmailTemplates.DefaultMessage),
edited under Settings → E-mail → QSL card e-mail. qslVars falls back to it when
the QSO's own QSLMSG is empty, so a per-QSO message always wins. Single choke
point covers both live preview and send.
2026-08-07 10:36:57 +02:00
rouggy e2bfe73bdb fix(backup): back up the contacts (logbook), not just the settings db
Since the logbook was split into its own SQLite file, backup.Run was still
snapshotting a.db (the settings/config database) — so the scheduled and manual
backups silently stopped including the QSOs. The operator was backing up config
and thinking it was their log.

Track the resolved logbook file path (a.logDbPath, set in connectLogbook) and
route the backup through a new runConfiguredBackup: the CONTACTS become the
primary "opslog-*" backup (the logbook file on SQLite, an ADIF export on MySQL),
and the settings/config db is snapshotted separately as "opslogcfg-*" so nothing
is lost. backup.Run takes a name prefix; the two sets rotate independently.
2026-08-06 23:22:04 +02:00
rouggy cfe5d6f2a7 chore: release v0.23.7 2026-08-06 18:06:04 +02:00
rouggy 761f554ac0 fix(kenwood): keep the CAT link up while transmitting (K3 shared-CAT FT8)
A K3 (and other Kenwood-dialect rigs) answers "?;" to an IF; status poll while
it is transmitting. ask() latched that as "IF unsupported" and ReadState
returned an error, so the Manager dropped the whole CAT link mid-transmit — the
log shows connected=false / "IF rejected" the instant JTDX sent TX;. That tore
down the shared rigctld CAT the digital-mode software keys through.

Two fixes: (1) track PTT (SetPTT) and skip the wire poll while it's held —
ReadState hands back the cached last state, capped at 30 s so a missed
SetPTT(false) can't freeze it; (2) never latch IF/ID as unsupported — those are
universal on Kenwood/Elecraft, so a "?;" to them is a transient busy (mid-TX),
not a missing command.
2026-08-06 17:49:46 +02:00
rouggy 01dcd91253 fix(motor-antenna): don't inhibit TX on a band the antenna doesn't cover
The follow filter correctly leaves the antenna put on an un-ticked band, but the
TX-inhibit loop ran independently: it gagged FlexRadio transmit whenever the
antenna reported "moving" (a stray polled Moving flag, or a move finishing from
the previous band), even on a band OpsLog was deliberately not managing. An
operator working 15 m on another antenna had their FT8 cut mid-transmission by
an "antenna moving" interlock.

motorTXInhibitLoop now takes the covered-band set and forces moving=false when
the current rig band isn't in it — un-ticking a band means hands off entirely:
no tune AND no inhibit. Also correct the RCU-01 references to RCU-06 (the actual
controller behind the short 11-byte status frame).
2026-08-06 17:06:49 +02:00
rouggy 82ce3353c4 feat(rotator): add Hy-Gain DCU-1 backend (RotorCard DXA, Rotor-EZ, Green Heron)
New internal/rotator/dcu1 client speaking the DCU-1 command set (AP1nnn / AM1
to go-to, AI1 to read bearing), over a serial COM port (4800 baud default) or a
raw TCP serial-over-IP bridge. Azimuth-only; Stop re-commands the current
bearing since the base set has no stop opcode.

Wired through app.go (normRotorType, default port 4001, GoTo/Heading/Stop/test
switches, park returns the same "PstRotator only" note as ARCO) and exposed in
the rotor settings as "Hy-Gain DCU-1 (RotorCard DXA, Rotor-EZ, Green Heron)"
with the ARCO's serial/TCP transport chooser and a bilingual hint. Protocol is
implemented from the standard DCU-1 spec and still needs field confirmation
against a real RotorCard DXA.
2026-08-06 10:40:36 +02:00
rouggy 62cdabe114 feat(relay): accept a full URL host so relays work behind an HTTPS proxy
Network relay boards (WebSwitch/KMTronic/Dingtian) were always reached at
http://<host>, so a board on the LAN behind a reverse proxy — the common remote
setup where the operator's 80/443 already go to Nginx Proxy Manager — couldn't be
reached from outside. relayBase() now keeps a scheme the operator supplies
(https://relay.example.com, optional sub-path) and only defaults to http:// for a
bare host/host:port. UI hint + test added.
2026-08-06 09:26:16 +02:00
rouggy fbd323af26 fix(pgxl): fan mode needs the "setup" prefix — "setup fanmode=VALUE"
Confirmed live: "setup fanmode=CONTEST" is accepted (reply code 0) while the
bare "fanmode=CONTEST" we switched to earlier is rejected (0x50000015), so the
fan mode snapped back and never changed on the amp. Restored the "setup " verb
and now check the reply code, returning an error if the amp rejects the set.
2026-08-05 17:32:53 +02:00
rouggy 16e64fd7b7 fix(ultrabeam): accept an 11-byte status frame from older controllers
An older controller behind an RS232-to-Ethernet bridge returns the status frame
without its trailing FreqMax byte (11 bytes, not 12). The packet checksum is
still valid, so it's a real short frame, not a fragment. queryStatus now accepts
>= 10 bytes and defaults the missing FreqMin/FreqMax rather than rejecting it as
"too short", which reconnect-looped the link. Whether the byte LAYOUT is
otherwise identical across controller versions still needs confirming from the
protocol reference.
2026-08-05 14:49:52 +02:00
rouggy d0f25aea9b feat(cluster): "already worked only on the same slot" option
New DX Cluster setting (Settings → DX Cluster). Off (today's behaviour) a call
worked anywhere reads as already worked; on, the WORKED-call flag needs the same
band AND mode. It folds through the digital-mode grouping (Settings → General):
grouped, a 20m FT8 contact also marks a 20m FT4 spot worked; ungrouped they are
separate slots. Backend: qso.WorkedCallSlotKeys builds CALL|band and
CALL|band|mode(grouped) keys; ClusterSpotStatuses uses them when the option is on
(a spot with no inferable mode falls back to same-band).
2026-08-05 14:11:06 +02:00
rouggy f91b83ee12 fix(awards): upper-case the DXCC main prefix (3D2/c → 3D2/C)
cty.dat spells some sub-entity suffixes in lower case; the awards prefix column
now shows them upper-cased like every other DXCC prefix.
2026-08-05 14:05:09 +02:00
rouggy a554257d5f feat(entry/stats/awards): Alt+W clear, slot drill-down, DXCC prefix column
Five operator-requested items:

- Alt+W clears the QSO entry. Handled before the `typing` guard and above
  the keyer's key routing, so there is always one key that clears whatever
  else is running — Esc is not that key when the CW keyer reserves it.

- The Grid box no longer pops outside the entry panel on a narrow window.
  Row 2 needed 300+130+76+gaps = 538 px inside a panel whose min-width is
  520, so Grid was pushed out and clipped at every narrow width, not just
  extreme ones. QTH's min-width drops to 80 and the row wraps rather than
  overflowing if it ever still can't fit.

- Selecting a QSO in the log now drives the Stats (F1) matrix. Uses its own
  WorkedBefore call into separate state, NOT runWorkedBefore: that one owns
  the entry form's wbRef and can trigger a field backfill, which browsing
  the log must never do. The entry form wins whenever it holds a call.

- Clicking a coloured band/mode square lists the contacts behind it. Returns
  the exact callsign AND the rest of the entity, because that pair is what
  the cell's colour encodes; the call's own QSOs are bolded. The DXCC arm
  matches the stored dxcc column only — reconstructing it from the callsign
  here would disagree with the matrix above, which is built from that column.

- The Awards DXCC list shows each entity's primary prefix in its own sortable
  column. Derived live from cty.dat into Ref.Group rather than stored on the
  reference row, so an existing installation needs no re-seed.
2026-08-05 13:47:36 +02:00
rouggy a20d9a0b76 fix(spe): drop the link on power-off so status shows off and ON works
Switching an SPE amp off left the already-open connection reading as connected
(the amp stops answering once off, but the stale open handle kept the status at
"connected"), so the panel never showed OFF and PowerOn — which only wakes a
DISCONNECTED amp, and must NOT pulse RTS/DTR on a running one — did nothing
until the operator restarted OpsLog. PowerOff now drops the connection and marks
the amp offline, exactly as a fresh start would; the poll's plain reopen never
wakes a switched-off amp, so it stays off until the ON button's RTS/DTR edge.
2026-08-05 11:02:44 +02:00
rouggy 9f5c482667 fix(catshare): echo PTT state so JTDX doesn't drop transmit
JTDX polls get_ptt DURING transmit to confirm the rig is keyed (WSJT-X does not,
which is why it worked and JTDX cut after ~2 s). We answered a blanket "0" (RX),
so JTDX concluded PTT had failed and dropped the over. get_ptt now echoes the
last PTT state commanded via set_ptt — always consistent with the client's own
command. Trace showed T 1 → three t→"0" polls → T 0.
2026-08-05 09:55:27 +02:00
rouggy b9ea077a64 fix(catshare): revert FT8 freq echo — it blocked JTDX transmit
The optimistic get_freq echo added in 0.23.5 (to stop the "Fake It" dial creep)
stopped JTDX/WSJT-X from going into transmit: the client reads frequency back
during its TX sequence, and echoing the commanded value instead of the rig's
live value interfered with it. No-TX is far worse than a 0.5 kHz drift, so revert
to reporting the rig's live frequency. get_freq/get_split_freq return s.rig.Freq()
again; the echo state, noteSetFreq, reportedFreq and the drift test are removed.
2026-08-05 09:26:33 +02:00
rouggy 821883dfd3 fix(ultrabeam): flush stale replies (not seq-match) + instant moving flag
The antenna does NOT echo our sequence number — its replies carry their own
counter — so the previous seq-matching drained every reply and stalled status
updates. Revert to reading one reply per command, but flush any bytes left in
the stream before each command (drainStale): a reply left by a timed-out command
is discarded so the next read stays 1:1. readPacket also resyncs to the next STX.
This fixes the intermittent disconnects, phantom frequency jumps and wrong
element-length readings without depending on the seq.

Also: report motion for a short window right after a commanded move, so the
"moving" indicator and the Flex TX-inhibit fire the instant a band/pattern is
clicked instead of a poll (~2 s) later; the real motor state takes over once
polled.
2026-08-05 00:13:53 +02:00
rouggy 98f11ee3d0 fix(ultrabeam): match replies to requests by seq (stop stream desync)
sendCommand discarded the reply's sequence number and accepted whatever frame
came back. On a slow remote link a command that timed out left its late reply in
the stream, and the NEXT command read it as its own — crossing STATUS with
READ_BANDS/PROGRESS. That surfaced as phantom frequency jumps (a spurious
follow-loop re-tune), intermittent "reply too short" disconnects, and wrong
element-length readings (READ_BANDS getting the status frame).

Now every reply is matched to its request seq and stale/malformed frames are
drained (bounded), with readPacket resyncing to the next STX. Tested with a
net.Pipe that injects a stale reply ahead of the real one.
2026-08-04 23:56:42 +02:00
rouggy ede81d3926 fix(catshare): stop FT8 dial drift in shared CAT (rigctld freq echo)
A digital app (JTDX/WSJT-X) sharing OpsLog's rig in "Fake It" split follows
the dial by polling get_freq. Freq() is the last polled value and lags a
set_freq by a poll cycle, so right after a transmission the client read the
still-shifted frequency, mistook it for a manual QSY and adopted it — the dial
crept down every over and never came back. get_freq now echoes the last
commanded frequency until the rig confirms it (or a short deadline passes),
closing the race. Backend-agnostic, so it fixes every rig, not just Kenwood.
2026-08-04 23:02:44 +02:00
rouggy bb3542c920 fix(ultrabeam): hold a commanded pattern over a remote link until confirmed
Changing Normal/180/bi over a remote connection reverted to the old pattern
after ~4s: the fixed 4s optimistic window expired while the motors were still
flipping the elements, and the lagging remote status poll then overrode the UI.
Hold the commanded direction while the motors are moving, then a short grace
window after they stop for the confirmation poll to land (SteppIR already used
a generous 45s hold, which is why only Ultrabeam-remote hit this).
2026-08-04 18:56:21 +02:00
rouggy 95482ec1d8 feat(cat): per-rig Kenwood/Elecraft data-mode choice (USB / MD6 / keep)
No single Kenwood mode digit fits every rig for a data mode: a K3/K4 wants
DATA (MD6), a TS-590SG/TS-990S data mode is a USB modifier set on the rig,
and MD6 on a plain Kenwood is FSK/RTTY. So the operator now chooses in
Settings → CAT: USB (default), DATA (MD6), or leave the rig's mode unchanged.

Only soundcard/data modes (FT8, PSK, JT…) follow this; RTTY/FSK stays its own
native mode, and voice/CW are untouched (isKenwoodDataMode + test).
2026-08-04 18:14:26 +02:00
rouggy 500fe8bfec fix(cw): activate the Kenwood/Elecraft keyer engine when selected
The frontend engine loader had no "kenwood" case, so a saved engine of
"kenwood" fell through to the WinKeyer default — the Kenwood/Elecraft
CW-over-CAT engine never ran even though the setting showed it selected.

Also clarify the Kenwood data-mode comment: there is no single mode digit
right for both a K3 (DATA=MD6) and a TS-590SG (MD6=FSK), so data stays on
USB as the safe common base; a rig-specific DATA mode is a follow-up.
2026-08-04 17:59:30 +02:00
rouggy 87ff0a9e16 chore: release v0.23.3 2026-08-04 16:46:32 +02:00
rouggy 18f9b915c5 fix: PGXL meters/auth/fan, TCI spots+click, PTT-over-CAT, CW <LOGQSO>
- PGXL: remote AUTH password; direct-link meter fallback (VITA-first) with
  250 ms poll + peak-hold; fan mode uses bare "fanmode=" (was ignored).
- TCI: spot colour sent as decimal ARGB (ExpertSDR dropped the hex string);
  spot click handled via CLICKED_ON_SPOT / RX_CLICKED_ON_SPOT to fill the entry.
- FlexRadio: clicking an OpsLog spot on the panadapter now applies the mode too.
- Filter presets: the trash icon deletes again (Radix pointer-down intercept).
- PTT hotkey: keys over CAT when a backend is active (was hijacked by a stale
  Audio-tab RTS/DTR serial setting); AltGr keys allowed; presses logged.
- CW macro <LOGQSO>: logs after the preceding CW is sent, not on the first letter.
2026-08-04 15:55:10 +02:00
rouggy b3fdd0b7fa feat(rotator): multiple rotors of any type, plus a CAT PTT hotkey
Settings -> Rotator is now a list like the amplifiers: add/remove rotors,
mix PstRotator / Rotator Genius / ARCO, and a Rotator Genius can drive both
its ports (one entry = two rotors). The compass gains a rotor selector, and
a per-rotor motorized-antenna flag so the boom/pattern paths show only for
the rotor carrying the Ultrabeam/SteppIR.

Also in this batch: a keyboard PTT hotkey (hold-to-talk or toggle, reusing
the audio PTT method with a CAT fallback), and TCI spot push to the
panadapter with click-to-fill of the callsign.
2026-08-04 09:01:21 +02:00
rouggy 9846354bf9 chore: release v0.23.2 2026-08-02 23:51:46 +02:00
rouggy 72f692aa04 chore: release v0.23.0 2026-08-02 20:03:16 +02:00
rouggy f6cd6e999a chore: release v0.22.9 2026-08-02 06:40:10 +02:00
rouggy 5777c119cb feat(cat): make the DTR/RTS lowering a setting
Both defaults break someone. 0.22.7 lowered the lines on Yaesu and
Kenwood and silenced a TS-990 whose interface needs RTS raised to
transmit; 0.22.8 stopped lowering them and an FT8 station reported its
output power wandering, cured by closing OpsLog — Windows raises both on
open and the interface reads one as PTT.

So it is now a checkbox on those two backends, off by default: that is
how they behaved before any of this. Xiegu keeps lowering them
unconditionally (its own report, its own explicit keying setting), and
the CI-V backend keeps the behaviour it has always had.
2026-08-01 19:25:04 +02:00
rouggy 0e1e7d9f3c feat(cat): ID 022 is a TS-990S
Reported by one in the field. Kenwood's documentation gives 024 for that
radio; both are mapped rather than betting on which is right, and the log
no longer reads "Kenwood (022)".
2026-08-01 12:09:57 +02:00
rouggy 3dd428d748 fix(cat): stop deasserting DTR/RTS on Kenwood and Yaesu
d4bfd30 fixed a Xiegu G90 behind a DE-19 that keyed on connect, and I
applied the same line-lowering to Kenwood and Yaesu with no evidence that
either needed it. It silenced them: many USB-serial interfaces will not
transmit with RTS low — hardware flow control, or an output stage the
line enables. A TS-990 on COM3 opened cleanly and answered nothing, which
reached us as "CAT stopped working after the update".

Xiegu keeps the behaviour: that is where the fault was reported, and that
backend now has an explicit setting for which line keys the rig. The CI-V
backend keeps its own, which predates all of this.

Kenwood also distinguishes a silent port from one sending data that never
answers, and quotes what arrived — "the rig is not answering" sent an
operator checking the power switch on a radio whose frames were visibly
on the wire.
2026-08-01 12:09:11 +02:00
rouggy c62d992ad6 fix(cat): keep the Kenwood read buffer across commands; log the CAT error
A TS-480 connected, answered ID, then never reported a state:

  discarding " 000000000010000000;" while waiting for IF
  connected on COM3 @ 115200 baud
  cat:state → connected=false freq=0

A headless frame tail can only come from bytes that were thrown away.
ask() buffered into a local slice, so everything left after the matched
frame — including the head of a frame still arriving — went with it, and
the link could sit one answer behind its questions. The buffer now lives
on the backend, and Connect drains whatever the rig said before AI0 took
effect rather than inheriting it.

Also: the cat:state diagnostic prints RigState.Error. It read
"connected=false freq=0" and said nothing about why, so every report of a
CAT failure arrived without the one fact that explains it — the reason
only ever reached a tooltip.

New work moves to 0.22.8; 0.22.7 is released.
2026-08-01 12:04:32 +02:00