rouggy 500fe8bfec fix(cw): activate the Kenwood/Elecraft keyer engine when selected
The frontend engine loader had no "kenwood" case, so a saved engine of
"kenwood" fell through to the WinKeyer default — the Kenwood/Elecraft
CW-over-CAT engine never ran even though the setting showed it selected.

Also clarify the Kenwood data-mode comment: there is no single mode digit
right for both a K3 (DATA=MD6) and a TS-590SG (MD6=FSK), so data stays on
USB as the safe common base; a rig-specific DATA mode is a follow-up.