Files
OpsLog/internal/cat/omnirig_vfo_test.go
rouggy 405b0e24cf feat: network audio into the QSO recorder, and a Yaesu that stays on its VFO
An Icom reached over the LAN streams its receive audio through the Icom
protocol, and Windows sees no sound card for it at all — the audio settings
could only offer the PC's own microphone, so "From radio" had nothing right to
point at and the QSO recorder had nothing to record. The recorder now accepts a
PUSHED source: the decoded stream goes to the speakers and to the recorder
alike, with no virtual cable to set up. Which source it uses follows the CAT
backend, and it is restarted only when that answer changes, so an ordinary
settings save never cuts a recording in half.

OmniRig no longer sends SetSimplexMode to a Yaesu when tuning. It is a silent
no-op on some — an FT-891 logged OK on every spot click while FreqA never
moved — and actively harmful on others. From an FT-2000 log, one QSY:

	Vfo="AB"(0x80)  Split=0x10000 (off)   the operator's state
	Vfo="BA"(0x100) Split=0x8000  (ON)    after SetSimplexMode

The rig-agnostic "receive and transmit HERE, simplex" call turned split on and
moved reception to VFO B. OpsLog then displayed B — reading the radio correctly,
after having moved it itself. Icom is untouched: there the call is the
authoritative one and the direct write is unreliable.

Also:
  - the NEW county badge shows in the entry form itself, inside the field,
    where the operator is deciding whether to call.
  - the basemap buttons clear the zoom controls; Light sat a few pixels from
    the minus button and was being clicked by mistake.
  - French cluster status: DÉJÀ CTC reads DÉJÀ QSO.
2026-08-23 10:43:11 +02:00

149 lines
7.4 KiB
Go

package cat
import "testing"
// Every known rig's OmniRig behaviour, pinned. These rules genuinely contradict
// each other between models, so a change that fixes one rig must be shown not to
// break another — that is what this table is for.
func TestResolveOmniRigVFOs(t *testing.T) {
const (
a14200 = 14200000
b14205 = 14205000
b21000 = 21000000
)
cases := []struct {
name string
rig string
main, fa, fb int64
vfo string
split int64
sticky bool
wantTX, wantRX int64
wantSplit bool
}{
// The reported failure: FTDX101D, SUB VFO pressed. OmniRig names VFO B and
// reports it as the generic Freq; freqA still holds the main VFO. Preferring
// freqA meant the display never followed the operator to B.
{"FTDX101D on SUB VFO", "FTDX101D", b14205, a14200, b14205, "B", pmSplitOff, false, b14205, 0, false},
{"FTDX101D on MAIN VFO", "FTDX101D", a14200, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
// Yaesu fallback for a rig file that names NO VFO at all (the stock FTDX10
// one, confirmed 2026-07-26): the generic Freq matching FreqB is then the
// only sign that the operator is on SUB. It applies ONLY when the enum is
// silent — when the enum names a VFO, the enum wins (pair cases below).
{"FTDX10, no enum, generic Freq is B", "FTDX10", b14205, a14200, b14205, "", pmSplitOff, false, b14205, 0, false},
// Same alternating ini: one poll says OFF while the rig IS in split. The
// latched ON flag has to survive the contradicting sample.
{"FTDX101D split, contradicting OFF sample", "FTDX101D", a14200, a14200, b14205, "AB", pmSplitOff, true, b14205, a14200, true},
// The latch must not manufacture a split out of a stale cross-band VFO B.
{"FTDX101D latch, VFOs on different bands", "FTDX101D", a14200, a14200, b21000, "AB", pmSplitOff, true, a14200, 0, false},
// Pair enums: first letter is the VFO being listened on. Reported by the
// whole Yaesu family; ignoring them pinned the display to VFO A (F4NBZ,
// 2026-07-26 — Log4OM follows SUB on the same rig through OmniRig).
{"pair enum BA, simplex → listening on B", "", b14205, a14200, b14205, "BA", pmSplitOff, false, b14205, 0, false},
{"pair enum BB, simplex → listening on B", "", b14205, a14200, b14205, "BB", pmSplitOff, false, b14205, 0, false},
{"pair enum AB, simplex → listening on A", "", a14200, a14200, b14205, "AB", pmSplitOff, false, a14200, 0, false},
{"pair enum AA, simplex → listening on A", "", a14200, a14200, b14205, "AA", pmSplitOff, false, a14200, 0, false},
// F4?? IC-7610 report, 2026-07-27: the operator's custom rig file declares
// VFO B permanently while they work on the MAIN VFO. OpsLog then wrote to A
// (SetSimplexMode acts on main) and read B — "the frequency never follows
// the knob". Honouring the enum is right in general, which is why the cure
// is an explicit override in the settings, applied before this function.
{"IC-7610 file wrongly says B — enum honoured, hence the override", "IC-7610", 0, 7150000, 14295000, "B", pmSplitOff, false, 14295000, 0, false},
{"same rig with the override forcing A", "IC-7610", 0, 7150000, 14295000, "A", pmSplitOff, false, 7150000, 0, false},
// Non-regression: a rig that does not report the VFO enum keeps the old
// order — freqA, then the generic Freq, then freqB.
{"no VFO enum, freqA populated (Yaesu/Kenwood)", "FT-891", a14200, a14200, 0, "", pmSplitOff, false, a14200, 0, false},
{"no VFO enum, only generic Freq (IC-9100)", "IC-9100", a14200, 0, 0, "", pmSplitOff, false, a14200, 0, false},
{"IC-7610: generic Freq reports B, enum says A", "IC-7610", b14205, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
// Split: PM_SPLITON must be read as a BIT. An exact == 0x8000 reported "no
// split" for any rig that sets the flag alongside another bit.
{"split, ON flag alone", "", a14200, a14200, b14205, "AB", pmSplitOn, false, b14205, a14200, true},
{"split, ON flag with extra bits set", "", a14200, a14200, b14205, "AB", pmSplitOn | 0x40, false, b14205, a14200, true},
{"listening on B → TX on A", "", b14205, a14200, b14205, "BA", pmSplitOn, false, a14200, b14205, true},
// Split must NOT be inferred when the rig says OFF, nor from a stale VFO B
// left on another band (the FT-710 / TS-570 false positive).
{"OFF flag, two distinct VFOs", "", a14200, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
{"ON flag but VFOs on different bands", "", a14200, a14200, b21000, "AB", pmSplitOn, false, a14200, 0, false},
{"ON flag but both VFOs identical", "", a14200, a14200, a14200, "AB", pmSplitOn, false, a14200, 0, false},
{"ON and OFF both set — ambiguous, treat as no split", "", a14200, a14200, b14205, "A", pmSplitOn | pmSplitOff, false, a14200, 0, false},
}
for _, c := range cases {
tx, rx, split := resolveOmniRigVFOs(c.rig, c.main, c.fa, c.fb, c.vfo, c.split, c.sticky)
if tx != c.wantTX || rx != c.wantRX || split != c.wantSplit {
t.Errorf("%s:\n got TX=%d RX=%d split=%v\n want TX=%d RX=%d split=%v",
c.name, tx, rx, split, c.wantTX, c.wantRX, c.wantSplit)
}
}
}
// Which VFO a frequency set writes to, and whether it may call SetSimplexMode.
//
// Reported on an FTDX101 (F4NBZ, 2026-07-29): listening on SUB, clicking a
// cluster spot dragged the radio back to MAIN. SetSimplexMode means "receive and
// transmit here, simplex" and OmniRig applies it to the MAIN VFO — so it must
// not be used when the operator is on SUB. They chose that VFO deliberately; a
// spot click asks for a frequency, not for a VFO change.
func TestOmniRigWriteTarget(t *testing.T) {
// Mirrors the decision made in SetFrequency.
target := func(vfo string) (prop string, simplexAllowed bool) {
onSub := vfo == "B" || vfo == "BB" || vfo == "BA"
if onSub {
return "FreqB", false
}
return "FreqA", true
}
cases := []struct {
vfo string
prop string
simplex bool
}{
// On the main VFO nothing changes: SetSimplexMode is what moves the Icoms
// whose direct writes are ignored.
{"", "FreqA", true},
{"A", "FreqA", true},
{"AA", "FreqA", true},
{"AB", "FreqA", true},
// On SUB, write FreqB and leave the VFO selection alone.
{"B", "FreqB", false},
{"BB", "FreqB", false},
{"BA", "FreqB", false},
}
for _, c := range cases {
prop, simplex := target(c.vfo)
if prop != c.prop || simplex != c.simplex {
t.Errorf("VFO %q → write %s, simplex=%v; want %s, simplex=%v",
c.vfo, prop, simplex, c.prop, c.simplex)
}
}
}
// SetSimplexMode is skipped on Yaesu, and that is not a preference.
//
// On an FT-891 it returned OK on every spot click while the rig never moved. On
// an FT-2000 it did something worse — a log of one QSY shows the state going
// from Vfo="AB" split off to Vfo="BA" split ON, so the operator's reception
// jumped to VFO B and OpsLog, reading the radio correctly, displayed B. The
// direct FreqA/Freq write does the tuning on these rigs.
func TestYaesuRigsAreRecognisedForTheSimplexSkip(t *testing.T) {
for _, yes := range []string{"FT-2000", "FT-891", "FTDX10", "ftdx101", " FT-991A "} {
if !isYaesuRig(yes) {
t.Errorf("%q not recognised as a Yaesu — SetSimplexMode would still be called on it", yes)
}
}
// Everything else keeps the call: on Icom it is the authoritative one.
for _, no := range []string{"IC-7610", "TS-590", "K3", "", "Flex-6600"} {
if isYaesuRig(no) {
t.Errorf("%q wrongly treated as a Yaesu", no)
}
}
}