The 0.22.3 block had grown into explanations: why a fault happened, how it was
found, what it does not cover. That belongs in the commits, where it already is.
An operator opens this list to learn what changed for them. Sixteen entries now
say it in a line each.
Settings → General, beside the language. An operator reading 2026-07-30 as the
7th of the 30th month is reading their own log wrongly, and that is a display
problem.
Storage stays ISO/ADIF, deliberately and permanently: it is what ADIF
specifies, it sorts correctly as text, and a stored format that followed a UI
preference would make the log unreadable the day the preference changed. Exports
and uploads are untouched.
Two details that decide whether it actually works:
- The columns are rebuilt when the format changes. The formatters are captured
inside AG-Grid's column definitions, so nothing else would notice and the
table would keep the old format until something forced a rebuild.
- main.tsx re-reads the choice after the portable prefs are pulled from the
database. The module reads localStorage at import time, which is BEFORE that
sync — so a copied data/ folder would have shown ISO until the next launch.
UTC is not part of the choice and never will be: a logbook is kept in UTC, and
showing local time would make the display disagree with the QSO's own record
twice a year.
Y green, N red, R blue — colour only, no pill or badge. These columns sit among
callsigns and dates, and a row of coloured boxes would shout louder than the
callsign it belongs to.
Twelve columns: paper QSL, LoTW, eQSL, Club Log, HRDLog, QRZ.com both ways, and
OpsLog's own card and recording flags. All four views the operator named —
recent QSOs, worked before, NET Control, QSL manager — turn out to share this
one grid, so they are all covered by construction rather than by four edits that
could drift.
Semantic tokens rather than fixed colours, so the four themes follow and the
contrast stays right on the light ones. ADIF's I (ignore) is deliberately left
in the default ink: it is neither good news nor bad, and colouring it would put
it in one camp or the other.
Opt-in, off by default: neither service can undo it, and a local delete is not
always a statement about the world — a duplicate cleared out of a contest log
was never meant to change the DX's log.
The two APIs are not alike, and the difference decides what is possible:
- Club Log deletes by MATCH (callsign, exact timestamp, band number), so it
works for every QSO in the log, past or future. The band table is its own
list and is pinned by a test: a band mapped to the wrong number does not
fail, it points the delete at a different QSO.
- QRZ.com deletes ONLY by logid. So markExtUploaded now stores the LOGID it
already received on every upload — it was being logged and thrown away. A
QSO uploaded before this cannot be withdrawn from here at all, and the log
says so by name rather than leaving the operator to assume it worked.
Both run BEFORE the local delete, because both need the QSO's own fields to
find their copy and there is nothing left to ask with once the row is gone.
Neither can block it: the operator asked for the QSO to go, and a refusing
website is not a reason to keep it.
Reference stays the default: that is how award lists are published and how a
paper list is read. Description answers the other question an operator actually
has — "have I worked anything in Alicante" — which reference order scatters
across eight thousand rows.
Sorted where the filtered list is built, so the grid and list views inherit it
rather than each growing its own copy that could disagree.
localeCompare rather than a byte comparison, because these lists are Spanish,
French and Italian place names: "Ávila" belongs beside "Avilés", not after
"Zaragoza". References compare numerically for the same reason in reverse —
08019 must not sort between 0801 and 081.
The situation, in the operator's words: working VP2MAA, recording, and he asks
to hear his own signal. So: stop, play, and the recording is still saved with
the QSO.
Stopping FREEZES the take rather than ending it — nothing more is captured,
nothing is discarded, and logging writes the file exactly as before. Playback
reuses the voice keyer's path: same output device, same PTT keying and release
with its generation guard, so a replay cannot be cut short by a stale unkey.
Playing is refused while still recording. The transmitted audio would feed back
into the same take on any rig monitoring its own transmission, and stopping is
one click the operator has already made — it is their statement that the take is
finished, not a hoop.
The elapsed clock freezes with the recording and resumes from where it stopped,
because it now shows the LENGTH OF THE FILE rather than the time since the QSO
began. Only a fresh take returns it to zero.
A red dot in the slot the counter will occupy. Click it and the counter starts,
the dot disappears, and logging the QSO writes the file exactly as an automatic
recording would — the save path already keyed off an active take, not off the
setting.
With automatic recording disabled the capture engine is not idle, it is not
running at all, so a manual take starts it. Two consequences handled here:
- It is released again when the take ends — logged, cancelled, or dropped for
being a digital mode. An operator who records one contact does not expect
their microphone held open for the rest of the session. The release is a
deferred call at the top of the save path so every exit goes through it,
rather than one that has to be remembered at each return.
- There is no pre-roll. An automatic recording opens with the seconds BEFORE
the callsign was typed; a manual one can only begin now. The button's
tooltip says so, because otherwise the difference between two files is a
mystery to the person holding them.
The button only appears where it can work: devices configured, automatic
recording off, and a mode whose audio is worth keeping. That state is asked of
the backend rather than inferred from a preference in the interface, so the two
cannot drift apart, and it is re-read when settings are saved.
The list read "Yaesu (native CAT)", "Kenwood (native)", "FlexRadio / SmartSDR
(native)". Native says how OpsLog is built, which is our business; the operator
opening that menu is answering a different question — how is my radio plugged
in.
So: OmniRig, FlexRadio (API), Yaesu (USB), Kenwood (USB, network), Xiegu (USB),
Icom (CI-V USB), Icom (CI-V network), TCI. Shorter, and each entry now tells
someone with a cable in their hand which line to pick.
The same ASCII stream over a socket instead of a wire: ser2net, an
Ethernet-serial adapter, a Raspberry Pi at the radio. One TCP transport
presented as a serial port, so the backend keeps a single code path.
Explicitly NOT the radio's own RJ45. A TS-890 or TS-990 speaks Kenwood's
KNS/ARCP there — session, authentication, a different protocol — and that needs
one of those radios in hand to write honestly. The setting's help text says so,
because an operator who plugs in their TS-890's Ethernet port and types its
address deserves to learn that from the interface rather than from silence.
Two details that decide whether this is usable or maddening:
- A read deadline expiring is reported as "no data yet", not as an error. It
is exactly what a serial read timeout means to the caller; as an error it
would make ask() abandon a rig that is merely thinking.
- The log line names what was connected to. "connected on @ 0 baud" after a
network connect sends someone hunting a serial fault that does not exist.
The host wins over the COM port when both are filled: it is the more deliberate
setting, and silently preferring the wire leaves someone staring at an address
they typed and a radio that never answers.
From a Kenwood trace: IF answered mode digit 1 on 7.160 MHz, the backend read
LSB correctly, and the entry form showed no mode at all while the frequency
tracked perfectly.
Nothing was wrong in the backend. Radios report the SIDEBAND, and the station's
mode list holds SSB — so the value pushed into the selector was not in its own
list of options and nothing could match. Yaesu and Icom report the same way, so
this was never Kenwood-specific; it only surfaced there.
Normalising at the point where a rig-reported mode enters the form fixes every
backend at once, rather than editing three mode tables and the next backend
someone writes.
It is also the ADIF-correct direction, which matters more than the selector:
LSB and USB are SUBMODEs in ADIF, not modes. MODE=LSB is not a valid value and
is what would have gone to LoTW and eQSL.
An operator who has deliberately put LSB or USB in their own mode list keeps
them — the list is their statement of what they log, not ours.
The grey line has never been released, so its off-by-one-copy edge was never
something an operator saw. An entry for it would describe a defect that only
existed between two commits of the same unreleased feature — noise in the middle
of the list someone reads to find out what changed for them.
Same case for the bulk-update progress bar: the feature and the fix that made it
non-blocking are both new in 0.22.3, so they are now one entry describing what
it does. The menu rename goes there too rather than standing alone.
The map repeats the world sideways, and zoomed out several copies are on screen
at once. The rings span −180…+180 once, so the shading ended in a hard vertical
edge wherever the next copy began: it read as a rectangle laid over the planet
rather than as night.
Each ring is now drawn again shifted a full turn either way. Three copies cover
every zoom this map reaches and cost nothing — three more polygons on a canvas
layer.
Zooming the map to fit one world would have hidden it rather than fixed it, and
would have taken away the free pan and zoom the operator has.
Grey line — the day/night terminator and its twilight band, off by default,
redrawn every minute so a map left open all day is not silently wrong by
evening. Its own Leaflet pane below the overlays, non-interactive, so it never
hides the path or beam nor swallows a click.
The solar maths is pure and was checked against known positions before being
wired to anything: both solstices, the March equinox, the subsolar longitude at
12 UTC, and day/night at Paris, Tokyo, New York, Sydney and Reykjavik across
seasons and hemispheres. That last set is what caught the real bug: the equation
has TWO solutions per meridian and the naive branch put New York in daylight at
02:00 in December — the terminator at +63° where it belongs at −63°. A shaded
map that looks entirely plausible and is exactly mirrored. It now anchors on the
classical terminator and takes the branch nearest it, which is also what makes
the twilight band follow the terminator instead of jumping hemisphere.
Separately, from a Xiegu user: the protocol-trace checkbox does not stay ticked.
It is React state initialised to false on every mount, so a trace still running
came back unticked — the operator ticks it to "switch it on", which switches it
OFF, and the log they send contains no trace at all. Worse than a cosmetic bug:
it silently defeats the one tool asked for to diagnose their radio. Both boxes
(CAT and WinKeyer) now read their real state from the backend.
Two faults in the progress bar shipped an hour ago.
It was a modal. A hundred QSOs is a minute; a contest log is two thousand and
ten minutes, and for all of it the operator could do nothing else — while their
radio is on. It is now a card in the corner: same bar, same count, same
callsign, none of the imprisonment.
And the menu said "Update from QRZ.com" while the code has always walked EVERY
configured provider, falling through to HamQTH when QRZ answers not-found. The
label is now "Update from the callsign databases", which is what happens.
Noted while reading that code, NOT fixed here because it trades against the
user's API quota and is their call: this path goes through the lookup cache, so
a second run on the same callsigns re-reads the cache rather than reaching the
provider. The cache comment already argues the opposite for deliberate clicks —
"a lookup the operator asked for by clicking is a deliberate act and must reach
the provider" — and a right-click on a selection is exactly that.
Selecting the 102 contacts of a freshly imported contest log and updating them
from QRZ.com is 102 network round trips. Nothing moved on screen while it ran,
so the only honest reading was that the application had frozen — and the natural
response to that is to kill it, halfway through.
The backend now emits a progress event per QSO and the frontend shows the same
overlay the ADIF import uses: a bar, the count, and the callsign being queried.
The callsign is reported BEFORE the lookup rather than after. With a slow
provider that is the difference between "waiting on F4BPO" and a name that lags
one QSO behind whatever is actually taking the time — which would be the field
someone stares at while deciding whether it is stuck.
The overlay is cleared by the closing event and again in a finally, so neither
a completed run nor a failed one can leave it on screen.
Reported from a Flex in Kenwood CAT mode: frequency read perfectly, split never
appeared. Not every rig speaking this dialect fills IF's split bit.
Rather than guess which column that firmware populates, ask the question that
DEFINES split — is the transmit VFO a different VFO from the receive one — which
is exactly what FR and FT answer, and the same rule the Yaesu backend settled on
after several wrong turns. FR is also trusted over IF for which VFO is in use:
they are asked in the same breath, and a rig vague about the split bit may be
just as vague about the VFO field.
Cost is bounded: a rig that rejects FR/FT answers "?;" once and is never asked
again, so this is two short commands per poll only where it works. Both paths
are tested against the emulator — split found through FR/FT with IF silent, and
IF-reported split still working on a rig that refuses FR/FT without re-asking.
Also extends the CAT wire trace to the Kenwood backend, ASCII quoted so an empty
reply is visible as such: "" and ";" look identical unquoted, and telling them
apart is the whole question when a rig half-supports a command. If this fix is
not the whole story on real hardware, the trace is what will say so.
Nobody here owns a Kenwood, and a backend that has never completed a single
exchange is a guess however carefully it was written.
But this repository already contains the other half of the conversation:
internal/catemu ANSWERS this dialect, pretending to be a TS-2000 so an ACOM
amplifier follows OpsLog. The test's responder replies exactly as catemu does —
same FA/FB widths, same 38-character IF layout, same ID019 — so the two halves
are checked against each other instead of against my reading of a manual.
Connect adds a dialPort seam for this; nothing else changed in the backend.
Covered: model identification, simplex on A, everything following the VFO in
use when on B, tuning writing to that VFO rather than blindly to FA, split with
TX and RX the right way round (ADIF FREQ is the TRANSMIT frequency — swapping
them writes the wrong frequency into every logged QSO), the mode digit, and a
silent port reported as not answering rather than as a connected radio. The last
three are each a fault that actually reached a user through the Yaesu backend.
What this does NOT prove: that a real TS-590 answers on the same timings, or
fills every IF field the way its documentation says. That still needs a radio.
They searched only the rows on screen. With the grid holding the most recent
page, filtering a column for RSGB-IOTA across a 28 000-QSO log returned nothing
— which reads as "the log does not contain it", not "it is not on this page".
That is how an import that had worked perfectly came to be reported as broken:
the tool answered a narrower question than the one being asked, and said so
only by being empty.
The advanced filter queries the whole logbook and is the honest instrument. The
headers also get back the width the filter menu icon was taking, which is the
smaller reason but a welcome one on a grid this dense.
No saved filter can be stranded by this: the grid persists widths, sort and
visibility, never a filter model.
An operator worked the RSGB IOTA contest in another logger and got back records
carrying <STATE:5>EU005: N1MM-class software stores the received exchange in the
column its contest module uses, not the one ADIF reserves. Imported verbatim,
every QSO gains a US-state field reading "EU005" and the IOTA award sees
nothing — the reference is in the log, just not where anything looks for it.
The import dialog gains optional source → destination rows, prefilled with
STATE → IOTA since that is the case that prompted it. Applied to the RAW record
before conversion, so it works for promoted columns and Extras alike and the
destination is parsed exactly as if the file had carried it there.
Two rules, both from the same principle that the file outranks our guess:
- the source is CLEARED, so a reference does not linger in STATE where it
would show as the contacted station's US state in the grid and every export;
- a destination the file already filled is kept, judged against the record as
it ARRIVED — otherwise the result would depend on Go's map iteration order,
which is deliberately random.
The swap case in the test is what forced that second rule to be stated: "never
overwrite" and "exchange two fields" cannot both hold silently, so a destination
that is itself a mapping source is treated as an explicit swap and nothing else
is overwritten.
Two white-screen reports are open — one after logging a 10 GHz QSO, one on
starting a DVK auto-call — and neither could be investigated, for the same
reason: a render error emptied the window and left NOTHING. No line in
opslog.log, no dialog, nothing the operator could send but the words "white
screen". A fault the user cannot report is a fault that cannot be fixed.
So before hunting either trigger, the reporting path:
- An error boundary catches a render throw, writes the error and component
stack to the app log through the new LogUIError binding, and shows it on
screen — selectable, with Copy and Reload.
- Global handlers catch what a boundary cannot: throws from timers, event
handlers and rejected promises. An auto-call loop lives entirely in
callbacks, which is exactly where the second report came from, and those
leave no trace at all today.
It deliberately does not try to resume: React cannot promise sane state after a
render throw, and a half-working logger would be worse than a clear stop.
This does not fix either crash. It makes the next occurrence arrive with its
cause attached, which is the step that has been missing.
Reported on an IC-9100: the MOX button does not transmit, it sets split. The
source sends the PTT command (0x1C 0x00) and nowhere sends the split one (0x0F),
so the discrepancy is between what OpsLog sends and what the rig acts on — and
that link has already been shown, in the same operator's log, to lose frame sync.
Rather than guess from the command table, this adds what settled the WinKeyer
bug in one line: the actual bytes. Settings → CAT → Log the CI-V protocol writes
every frame in both directions as hex. RX is traced BEFORE framing, since the
bytes as they arrived are what reveals a lost boundary — a decoded view would
hide exactly the fault being hunted.
Session-only, like the keyer trace: it is a diagnostic, and a log full of hex
helps nobody who forgot it was on.
I am not claiming a cause yet. The last time I inferred one from a protocol
document rather than from evidence, I inverted a digit and broke the case that
worked.
From F4JND's log: a rig sitting on 145.550 MHz FM produced status lines reading
16445550000, 8364550000, 5817408364 and 12640 Hz between good readings — the last
of those even resolved to a 6 cm band.
BCDToFreq treated the nibbles 0x0A..0x0F as the digits 10..15, so a byte stream
that had lost frame sync still decoded into a number. The same log shows why sync
was lost: PTT round trips timing out and a scope stream the rig kept rejecting
(0x27), both competing with the poll on one serial line.
Non-decimal nibbles are now refused. Each caller keeps its last good value rather
than publishing noise: the frequency reader returns an error, the sub-VFO reader
returns not-ok, and the scope keeps its previous edges. Garbage that LOOKS like a
frequency is worse than a refused frame — it reaches the display, the band slots
and eventually the log, and it is the operator who then has to disprove it.
The test builds its fixture with FreqToBCD rather than by hand, because my
hand-written one was byte-reversed and the test caught it.
This does NOT explain the white screen that was also reported, and I have not
claimed it does: it removes one source of absurd values reaching the UI, which is
worth doing on its own evidence.
The 0.22.1 tag was cut at d98bb2e, and six commits landed after it. Five of them
had appended their entries to the 0.22.1 block, so the released changelog
promised things the released binary does not contain: the 4O3A marks, the
status-bar logbook path, the Yaesu per-VFO mode, ERC rotator support and the
Kenwood backend.
Those five move to a new 0.22.2 block, in the order they were written. The
0.22.1 block is restored to exactly the twelve entries the published tag holds —
verified against `git show v0.22.1:changelog.json` rather than by eye.
Worth noting for next time: entries are appended as work lands, so any commit
after the release tag needs its own block opened first. The mistake is silent —
nothing fails, the What's New dialog simply describes a version that never
shipped those changes.
A sixth CAT backend, talking to a TS-590/890/990/2000 over its serial port with
no OmniRig in between — frequency, mode, VFO, split and PTT. Elecraft K3/K4 and
the "Kenwood" setting on other radios speak the same dialect.
The protocol was not researched from scratch: internal/catemu already ANSWERS
these commands, pretending to be a TS-2000 so an ACOM amplifier follows OpsLog.
The IF frame layout here is read from the same format string catemu emits, so
the two halves of the repository agree by construction — and the test caught my
own fixture being one character short, which is exactly the error that layout
invites.
Design notes worth keeping:
- IF; is the poll. One frame carries frequency, TX state, mode, VFO and split,
so simplex operation costs a single round trip; the other VFO is only asked
for when split is actually on.
- FA/FB take ELEVEN digits here where Yaesu uses nine. That is the likeliest
place to copy the Yaesu backend and be wrong by a factor of a hundred, so it
has its own test.
- Every lesson the Yaesu backend learned the hard way is built in from the
start: replies matched to the command that asked, "?;" remembered so a poll
stops paying a timeout for an unsupported command, the serial handle closed
before reopening, and a rig that answers nothing reported as absent rather
than "connected".
Untested on hardware — I have no Kenwood here. The frame parsing is covered by
tests against catemu's own format.
An ERC (Easy Rotor Control, incl. ERC Mini) emulates Yaesu GS-232A/B, which is
exactly what the backend written for the microHAM ARCO already speaks — azimuth
out (Maaa), azimuth in (C), stop (S), which is the whole of what was asked for.
So this is two small gaps rather than a new backend:
- Serial speed was hardcoded to 9600. An ARCO's virtual COM ignores it, but an
ERC runs at whatever its own configuration sets, and a mismatch reads as a
dead rotator. It is now selectable beside the COM port.
- The entry was called "microHAM ARCO", so an ERC owner would never have found
it. It is named after the PROTOCOL now: "GS-232A controller (microHAM ARCO,
ERC…)".
The help text states the condition plainly in both languages, because it is the
one thing that will otherwise waste an evening: an ERC left on Hy-Gain DCU-1
speaks a different command set and simply will not answer.
Untested on hardware — I have no ERC here, and the GS-232 path itself is proven
on a real ARCO.
Reported, and reasoned out from the half that already worked: a spot click now
tunes the right VFO, but it set the mode with MD0 — main — whatever VFO the
operator was on. Working from SUB, the spot changed the mode of the VFO NOT in
use and left the one in use as it was. The author inferred the sub half from
seeing main change, and was right.
The read had the same fault, so the console displayed main's mode while showing
the sub VFO's frequency.
Mode now addresses the receiver in use — MD0 for main, MD1 for sub — in the poll
read, in SetMode, and in the console's raw-mode setter. A rig without a sub
receiver never sees MD1: curVFO only becomes B where the rig reports its receive
VFO in the first place.
Spotted by the author: on SQLite the database chip showed a.dbPath — the
settings/profile database — under a tooltip reading "Local SQLite logbook".
Those became two separate files when the logbook was split out, so an operator
checking where their QSOs live, or which file to copy before a trip, was pointed
at the wrong one. MySQL was already right.
It now resolves the logbook the same way connectLogbook does: the active
profile's own file if it names one, then the default logbook.db, and the settings
db only in the case where it genuinely doubles as the logbook.
Also moves the 4O3A mark beside its menu label instead of the far edge of the
row, as asked.
Antenna Genius and Tuner Genius now carry a small 4O3A wordmark, so the two
panels that drive that hardware are recognisable without reading the labels.
Drawn inline rather than shipped as an image file, following the language
picker's flags: it scales with the row, follows the theme through currentColor,
and adds no binary asset to the repository.
It is a plain wordmark, not the manufacturer's logo artwork — I did not pull an
image off the web, since I cannot verify the provenance or licence of what I
would find, and redistributing a company's mark inside the product is the
author's call. The component is one function and takes the official SVG in its
place if that is preferred.
Not applied to the Amplifier panel: it covers both the 4O3A PowerGenius XL and
the SPE Expert range, so a single vendor mark there would be wrong.
Reported: a 6 s auto-call gap gives clearly less than 6 s between the end of one
CQ and the start of the next.
The wait after sending watched only the keyer's busy signal. That signal travels
from the keyer to the window as an event, and the code gave it one second to
appear before giving up — if it had not arrived and cleared by then, the wait
ended immediately and the gap ran from the START of the call. A 6 s gap after a
4 s CQ becomes about 2 s of silence, which is exactly what was heard.
The message's own duration is now a FLOOR: the wait runs at least the estimated
sending time, and the busy signal only extends it (slow link, long buffer),
capped as before. The estimate can only be approximate, but it cannot be skipped
by a late event, and erring long costs a slightly wider gap rather than a call
that steps on the previous one.
Reported on an FTDX101: with RX and TX moved together to the sub VFO, OpsLog
showed split — and took the MAIN frequency as the transmit one, which would log
the wrong frequency.
ST is a bare flag. It says "split" without saying which VFO transmits, and this
rig raises it whenever the transmit VFO is the sub one, whether or not the
operator is also listening there. FT names the transmit VFO, so where the receive
VFO is known as well (FR), split is derived from the pair: they differ or they do
not. That is a fact about the rig's state rather than a flag whose meaning varies
by model.
The fix is therefore in the probe ORDER, not in the reading: FT is asked first
when FR answered, and ST stays the fallback for rigs that have neither. A test
pins the order and both halves of the trap — that FT gets this case right, and
that ST alone gets it wrong.
The seven minutes of reconnects in the operator's log turned out to be the radio
switched off — no defect. But the log said otherwise:
20:14:42 yaesu: ID query failed (timeout) — continuing…
20:14:44 yaesu: connected on COM7 @ 38400 baud, model="FTDX101D"
Opening the port was treated as connecting, and the model name was left over from
the previous session, so a powered-down rig produced a line claiming it was
connected as a named model. That is what sent me looking for a software fault.
Connect now tracks whether ANY probe answered. If none did, it clears the stale
model, says so in terms an operator can act on — is it powered on, is the CAT
rate right — and returns an error so the reconnect loop keeps trying rather than
believing it succeeded.
Connect assigned a fresh handle to y.port without closing the one it already
held. It is called again on every reconnect, so a rig that fails to answer leaks
one handle per attempt — every few seconds, indefinitely.
Windows opens a serial port EXCLUSIVELY, which makes this visible as "yaesu: open
COM7 @ 9600 baud: Serial port busy" in an operator's log: OpsLog was competing
with itself for the port.
This is a real defect found while reading the reconnect loop, but I want to be
straight about its limits: it does NOT explain the seven minutes of "ID query
failed — timeout" in the same log, where the port opened and the rig stayed
silent. That one is still open, and the operator alternates between two separate
radios (a TCI SDR and the Yaesu) rather than sharing one port, so a conflict
between backends is not the explanation either.
Reported both ways round, which is what settles it. With RX and TX on SUB
everything worked; with them on MAIN the frequency froze and a spot click tuned
the sub VFO. The log shows the rig answering FR01 in the MAIN case.
So on an FTDX101 the state is the FIRST digit — 0 = main — and the second is a
separate parameter. Yesterday I changed this to the LAST digit, which read FR01
as SUB and inverted the whole thing. The fault that change was meant to fix ("SUB
shows MAIN") came from reading VS instead of FR, and probing FR had already fixed
it on its own; the digit change was an unnecessary guess layered on a real fix.
Nothing else needed changing for the operator's two questions: the display and
SetFrequency already follow curVFO, so a spot now tunes whichever VFO holds RX
and TX, and the main frequency is read when on main. A test states that in those
terms — active VFO and which command a spot writes — rather than only as a byte,
because the byte is what I got wrong while believing the logic was right.
The log named the cause in one line: yaesu: receive VFO is read through FR
(answered "FR01;"). An FTDX10 answers "FR0;" — one digit — so reading the digit
straight after the prefix worked there and took the 0 of "01" on an FTDX101.
The rig was on SUB and OpsLog said MAIN, which is the reported "Sub shows the main
frequency". It also explains the second half: split is "TX VFO differs from RX
VFO", so a receive VFO that alternated between right and wrong made the split flag
flip between consecutive polls and swap freq and rx in the log.
The state is now taken from the LAST digit before the terminator, which is correct
on both forms, and the same reading applies to ST/FT/VS rather than leaving the
next two-digit rig to be found in the field.
On the operator's question of whether freq should simply be the active VFO: no —
freq is the TRANSMIT frequency by ADIF convention (FREQ is the QSO frequency,
FREQ_RX the receive one, set only when split). In simplex they are the same, so it
does read as the active VFO; in split it must stay the transmit VFO or the log
records the wrong frequency. What the operator saw was this bug, not that rule.
"Showing 10000 of 23683 matches · 28648 total" was read as a filter matching more
than the log holds. The numbers were right — 23 683 matches out of 28 648 QSOs,
capped at 10 000 displayed — but the middle one belonged to "matches" while
sitting where "of N" normally means the total.
Each number is now named where it appears: shown · match the filter · in the log.
Thousands separators too, since 23683 and 28648 are hard to compare at a glance.
No counting change: both counts run over the same table, so matches can never
exceed the total.
Reported: after a confirmation download they all turn to Y.
The test accepted qsl_rcvd = Y as a confirmation. That field is the operator's
OWN paper-QSL flag, which they uploaded to QRZ in the first place — so QRZ handed
it back and OpsLog read it as QRZ's answer. On a log full of paper cards that is
most of the log, which is exactly what was seen.
Only QRZ's own statement counts now: app_qrzlog_status = C, or the ADIF field
qrzcom_qso_download_status = Y that QRZ sets for it. LoTW and eQSL confirmations
are explicitly not accepted either — they are other services' answers, and the
column says QRZ.
This status feeds award slots, so a false Y is a QSO counted as confirmed when it
is not. That asymmetry is why the rule is narrow rather than generous, and the
test lists the negatives as deliberately as the positives.
The changelog warns that earlier downloads may already have set the column
wrongly — the fix stops it happening again but does not undo it.
Asked for as a missing feature. It is not missing — the "fill my station fields"
option has stamped the default QSL / LoTW / eQSL / Club Log / HRDLog / QRZ.com
statuses on empty fields since v0.14. What was missing is any mention of it: the
option's description talked only about MY_* fields, so the behaviour was
undiscoverable except by comparing a log before and after.
The description now says it, in both languages, and names why it matters — a
WSJT-X log carries almost no QSL fields.
The rule is also pinned by a test now, which meant splitting the fill from the
settings lookup: blanks are filled, existing values are never touched.
Overwriting them would erase confirmations the operator has actually received,
and that is the half a future edit is most likely to get wrong.
Describes what the operator gets: a spot click in DXHunter now moves the radio,
not just the callsign field. Notes explicitly that a packet without <FREQ>/<MODE>
behaves exactly as before — that is the reassurance anyone already using
remote_call needs, and it is the part a feature description usually omits.
Appended at the bottom of the block, per the rule adopted with 0.22.0: a version
is read top to bottom.
The operator's description separates the two cases precisely, and that is what
identifies the fault. RX alone on SUB displayed VFO B correctly; RX AND TX on
SUB — entirely on the sub receiver — displayed VFO A.
VS was being read as "which VFO is in use". On an FTDX101 it does not answer that
question: with both RX and TX on sub it still reported the main VFO. FR is the
command that selects the RECEIVE VFO, and it is now asked first, VS remaining the
fallback for models that lack it.
Split falls out of the same correction: split means the TRANSMIT VFO differs from
the RECEIVE one, so a wrong receive VFO made the comparison wrong too — which is
the second half of what was reported. A test covers all four RX/TX combinations,
including the one that is NOT split (both on sub) and reads as split if you take
the transmit VFO alone.
Translating the schema correctly does nothing for a database that already
exists. This operator's had been created by an earlier attempt, so qso.state was
already TEXT and every launch died on the same statement — CREATE INDEX … ON
qso(state), error 1170 — with the connection failing at startup and no way
forward from the UI.
Columns that MUST be VARCHAR (the indexed and keyed ones) are now converted
before the migrations run. It reads information_schema, touches only the columns
in varcharColumns, and only when they are actually TEXT — a no-op on a healthy
database, and it preserves each column's NULL/NOT NULL.
A failure to repair IS reported: it is the difference between a logbook that
opens and one that does not. A failure to READ information_schema is not — a
server that will not answer it can still be running a perfectly good schema, and
refusing to open would turn a non-problem into an outage.
The quoting fix was necessary but not sufficient: "column 'op_name' can't have a
default value" persisted.
The translation worked line by line and rewrote only the FIRST column on each
line. Our own migrations put one column per line, so nothing showed there — but
sqlite_master stores a table's CREATE statement with every ALTER-added column
appended to the SAME line, and the baseline is built from exactly that. On a
logbook that had been through upgrades, most columns therefore kept their TEXT
type and MySQL rejected the schema.
Two consequences fixed together: every match is now rewritten, and each one is
decided from ITS OWN declaration — the text between the surrounding commas —
rather than from the whole line. Deciding per line would have made every column
sharing a line with a default-bearing one into VARCHAR(255), which breaches the
InnoDB row-size limit the TEXT rule exists to respect.
Tests cover the many-columns-on-one-line shape and pin that a neighbour's DEFAULT
does not leak.
Two errors from a shared MySQL logbook, both fatal to the schema and neither
naming its cause:
CREATE INDEX … ON qso(state) → 1170 BLOB/TEXT column used in key
specification without a key length
op_name TEXT … DEFAULT '' → 1101 TEXT column can't have a default value
One root cause. TEXT columns are rewritten to VARCHAR(255) when they are indexed
or carry a default — that is exactly what those two MySQL rules require — but the
pattern only matched a BARE column name. The SQLite baseline dump quotes its
identifiers, and mysqlDDL turns those quotes into backticks before the TEXT rules
run, so every column coming from the baseline kept its TEXT type and MySQL
rejected the schema.
The operator saw none of this: just "MySQL is enabled but the connection failed
at startup" and a silent fallback to local SQLite — which is the worst shape for
a shared logbook, because each operator then logs into their own copy.
The pattern now accepts a quoted or bare name and puts the quoting back. A test
covers both forms, plus the case that must NOT change: an unindexed column stays
TEXT, since VARCHAR everywhere would break MySQL's row-size limit. Reverting the
one-line change makes it fail.
Reported on an FTDX101: the panel showed split ON with the radio OFF, and the
reverse — while the same model behaved correctly for another operator, and an
FTDX10 was fine throughout. That pattern is the clue: one operator was on MAIN,
the other on SUB.
The two commands say different things and were read alike:
ST is a split FLAG — ST1 means split, whatever VFO is in use.
FT names the TX VFO — FT0 = transmit on A, FT1 = transmit on B.
Split is on when the rig transmits on a DIFFERENT VFO from the one it listens to.
Reading FT1 as "split" is therefore correct only on VFO A, and exactly inverted
on SUB. It is now compared with the current VFO.
Writing had the identical fault, and it was worse: sending FT1 for "split on"
while the operator listened on SUB CLEARED the split it was asked to set. Both
directions are pinned by tests over each VFO state.
Reported on an FTDX101 (F4NBZ): listening on the SUB VFO, clicking a spot moved
the radio to MAIN.
SetSimplexMode is the first thing SetFrequency tries, and it means "receive and
transmit here, simplex" — OmniRig applies that to the MAIN VFO by definition. It
is there because several Icoms ignore direct FreqA/FreqB writes, so it stays for
the main VFO; on SUB it is now skipped entirely and FreqB carries the change.
The generic "Freq" property is skipped on SUB too: on several rig files it IS the
main VFO, so writing it would move the VFO the operator is not using — or pull
them back to it, which is the bug being fixed.
An operator on SUB put themselves there deliberately. A spot click asks for a
frequency, not for a change of VFO — that distinction is the whole fix, and a
test pins which property each VFO state writes.
Reported with screenshots: a dozen records lifted out of wsjtx_log.adi into a new
.adi imported as "0 imported, 0 ignored, 0 total". The parser only emitted
records after <EOH>, and a hand-assembled file has no header — so the whole file
was read as header text and thrown away. The count says the file was empty; there
is nothing on screen to suggest a missing tag, which is why this was reported as
"import does nothing".
An <eor> is proof that a record ended, header or no header. Fields are now
collected always and DISCARDED at <eoh> — that tag is exactly the statement
"everything before this was the header", so real headers stay out of the data
just as reliably, and a headerless file keeps its first record instead of losing
it to the same rule.
An existing test asserted the old behaviour. It encoded a defensible reading of
the spec, but the file it rejects is one operators really make and the rejection
is silent, so the test is rewritten with the evidence that changed it rather than
deleted.
New entries were being prepended, so a version block read backwards: an operator
met "the Yaesu meters are corrected" and "the console follows the mode" several
entries before learning that a Yaesu console existed. The fixes made sense only
to someone who had followed the development.
0.22.0 is reordered so each feature appears before what was fixed on it, and
CLAUDE.md now says to append at the bottom.
Restored the entry that INTRODUCES the Yaesu console: I had overwritten it when
editing the meters entry in place, so the release described corrections to a
panel it never announced.
The byte trace from a real WK2 settled in one line what no amount of reading
could: "TX 11 32". Command 0x11 is SET KEY COMPENSATION in milliseconds, not the
dit/dah ratio — that is 0x17. So a neutral ratio of 50 asked for 50 ms of extra
key-down on EVERY element. At 25 wpm a dit is 48 ms, so elements more than
doubled and ran into each other: the reported "it sends one element, then a long
pause".
The ratio now goes out as 0x17, and the compensation is explicitly set to 0 —
merely stopping the wrong command would leave an affected keyer misbehaving,
since it keeps the value in EEPROM until something writes over it.
The init sequence is now built by a separate function so the BYTES are testable,
and a test pins each command number. These numbers are the contract with the
hardware, and a wrong one produces a fault that cannot be diagnosed from the UI
at all — this one cost the operator weeks and needed a trace to find.
This is why the fix waited for the trace rather than being guessed: the plausible
guesses (mode register, sidetone, WK1-vs-WK2 differences) were all wrong, and any
of them shipped blind would have broken the keyers that work today.
Renamed from 0.21.9 at the author's request: this release adds native Yaesu and
Xiegu CAT, CAT sharing over Hamlib NET rigctl, a Yaesu console and a fifth CW
engine, which is a minor version rather than a patch.
The Yaesu keyer had two entries — one written when it was added, one when the
FTDX10 turned out to refuse it. Merged into the single statement an operator
needs: what it does, where to select it, and which rigs accept it.
The weak audio was not a level at all: the radio was still modulating from its
front microphone, so almost nothing of the USB feed reached the air. On an FTDX10
that is MENU → SSB MOD SOURCE = REAR.
Worth putting in the settings hint rather than leaving in a conversation — every
operator wiring a voice keyer for the first time meets it, and no amount of gain
in OpsLog can compensate for a rig listening to the wrong input.