Commit Graph
522 Commits
Author SHA1 Message Date
rouggy 3f82da3c18 feat(hamlog): mark an already-uploaded log through bulk edit
A log sent to hamlog.online by hand — an ADIF exported from OpsLog and dropped
on their site — had no way of being marked as sent afterwards. The QSL Manager
then listed every one of those contacts as backlog and offered to upload them a
second time.

Both HAMLOG keys join the bulk-editable extras, so a selection (or the whole
log) can be stamped in one pass. They are DATES rather than Y/N flags because
that is the shape the sent stamp already uses: the QSL Manager's backlog asks
whether the key is present, and a date also says when it went.

The test pins that they are reachable through the extras path and NOT offered as
columns — a mapping claiming both would write to a table that has neither.
2026-08-23 13:02:04 +02:00
rouggy cd557acf81 feat(hamlog): send to HAMLOG.online from the right-click menu
The upload targets in the QSO context menu gain HAMLOG.online, so a selection
goes there the same way it goes to QRZ or LoTW.

The confirmation toast now names the service from a map rather than a chain of
ternaries that stopped after three: hrdlog, eqsl and hamlog were echoed as their
internal ids, which is not what the operator clicked on.
2026-08-23 12:46:29 +02:00
rouggy 036dc53fe8 feat(hamlog): mark what has been sent, and a QSL Manager backlog
An upload now leaves a trace on the QSO: APP_OPSLOG_HAMLOG_SENT holds the day
it went. The date rather than a Y, so a log says WHEN — and so one shape serves
three readers: eligibility (a stamped QSO is not sent twice), the QSL Manager's
backlog, and the appearance rules' sent channel.

HAMLOG joins the QSL Manager's service list. It has no status column to select
on, so its backlog is the ABSENCE of that extras key — a LIKE over the extras
JSON, which is a full scan and is the right trade here: it answers a button an
operator presses, and the alternative is a promoted column for a field no other
program would ever read. The match is on the quoted key, so a QSO whose comment
merely mentions the text is not taken for one already sent — which is what the
test pins.
2026-08-23 12:40:09 +02:00
rouggy 73806cbd70 feat(hamlog): the settings panel, the key check, and a row-colour channel
HAMLOG.online is now reachable: Settings → External services → HAMLOG.ONLINE
takes the API key, the auto-upload switch and the timing, exactly like the six
services beside it, and a link opens the page where the key is issued.

The button next to it checks the KEY, not the connection. HAMLOG answers
KEYSTATUS with the callsign the key belongs to — something no other service
here offers — so the result reads "Key is valid — account F4BPO" rather than a
green tick. A key pasted from a club account or a second station is visible at
once, which is precisely the mistake a tick would have hidden.

No on-close timing, for the same reason as Cloudlog: there is no per-QSO upload
column to select a backlog from at shutdown, so the option would have done
nothing. Immediate or delayed, and a stored on_close falls back to immediate
rather than silently uploading nothing.

The appearance rules gain a HAMLOG.online channel too, so a row can be coloured
"confirmed" on that alone. It reads the ADIF extras — the standard names a field
for hamlog.EU and none for hamlog.ONLINE — using the same keys the award engine
reads, so the two can never disagree about what a confirmation is. "To send"
skips it: a QSO is either uploaded or not, there is no card to be owed.
2026-08-23 12:29:38 +02:00
rouggy ee148732dd feat: HAMLOG.online upload and confirmations, Yaesu antenna, a named port holder
HAMLOG.online is a seventh external service: one API key, one ADIF record per
QSO, immediate / delayed / on-close like the rest. They publish no API
documentation, so the protocol is read from THEIR OWN client — the HAMLOG Agent
(github.com/hamlogonline/Agent), which is the authoritative source short of
asking them:

	POST https://hamlog.online/api/agent/
	{"ADIFADD": {"APIKEY": k, "ADIFDATA": record}}   → {"STATUS":"OK"}
	{"KEYSTATUS": {"APIKEY": k}}                     → {"STATUS":"OK","CALLSIGN":…}

Success is STATUS == OK, not "no ERROR field": their failure carries ERROR and
no STATUS, and reading an unknown reply — a proxy page, a maintenance notice —
as an acceptance is how a contact goes missing without anyone noticing.

KEYSTATUS buys something no other service here offers: the key can be checked
BEFORE the first QSO, and the answer names the account. A key pasted from
another callsign is caught in the settings panel rather than through a week of
silent refusals.

Their confirmations are also an award source now, ticked like LoTW rather than
expressed through "custom". It reads the ADIF extras, not a column: the standard
names a field for hamlog.EU and none for hamlog.ONLINE, and borrowing the other
site's field would write a falsehood into every exported log. Three plausible
key names from their own export are accepted too, so nobody has to rename a
column by hand after an export.

Yaesu gains antenna selection (AN), remembered per band — the antenna picked on
a band comes back with it, with no table to fill in anywhere. Rigs with one
socket never answer AN and never show the row; the log says which case it is.

And a serial port that is refused now names its likely holder. OmniRig stays
resident once activated and keeps the port of the rig configured in it, so a
native backend never gets it — "Serial port busy" alone accused nobody, and an
FTDX10 spent a morning being blamed for it.
2026-08-23 12:18:27 +02:00
rouggy 405b0e24cf feat: network audio into the QSO recorder, and a Yaesu that stays on its VFO
An Icom reached over the LAN streams its receive audio through the Icom
protocol, and Windows sees no sound card for it at all — the audio settings
could only offer the PC's own microphone, so "From radio" had nothing right to
point at and the QSO recorder had nothing to record. The recorder now accepts a
PUSHED source: the decoded stream goes to the speakers and to the recorder
alike, with no virtual cable to set up. Which source it uses follows the CAT
backend, and it is restarted only when that answer changes, so an ordinary
settings save never cuts a recording in half.

OmniRig no longer sends SetSimplexMode to a Yaesu when tuning. It is a silent
no-op on some — an FT-891 logged OK on every spot click while FreqA never
moved — and actively harmful on others. From an FT-2000 log, one QSY:

	Vfo="AB"(0x80)  Split=0x10000 (off)   the operator's state
	Vfo="BA"(0x100) Split=0x8000  (ON)    after SetSimplexMode

The rig-agnostic "receive and transmit HERE, simplex" call turned split on and
moved reception to VFO B. OpsLog then displayed B — reading the radio correctly,
after having moved it itself. Icom is untouched: there the call is the
authoritative one and the direct write is unreliable.

Also:
  - the NEW county badge shows in the entry form itself, inside the field,
    where the operator is deciding whether to call.
  - the basemap buttons clear the zoom controls; Light sat a few pixels from
    the minus button and was being clicked by mistake.
  - French cluster status: DÉJÀ CTC reads DÉJÀ QSO.
2026-08-23 10:43:11 +02:00
rouggy f50806fbd9 feat: panadapter spots that read, a CI-V link that survives, no auto-call
Panadapter spots are now worth reading. The comment carries the spotter, the
entity and the status in DXHunter's own shape — "CQ up 2 [F4BPO] [Franz Josef
Land] [New Slot]" — which needed two things nothing documents: SmartSDR splits
its command line on SPACES, so the words ran together until every space became
non-breaking; and it truncates past ~60 characters, so the cluster's own words
are trimmed first and the three brackets always survive. RBN column padding is
collapsed on the way in, or a preserved run of spaces opened a gap wide enough
to push the rest off screen.

"Already worked" means the CALLSIGN is in the log, not the entity: saying it of
a station never contacted was simply wrong. Each status can also be kept off the
panadapter entirely, and the WSJT-X decode spots obey the same switches — the
palette governs the panadapter, not one of the two things that feed it.

And the radio is no longer hammered: a spot whose frequency, colour and comment
are unchanged is not removed and redrawn. A busy skimmer feed re-spots the same
station every few seconds; one two-minute session sent 2128 adds, 88 of them for
a single callsign, and the display did not move a pixel for any of them.

CI-V, from an IC-7850 that kept killing JTDX: a reply the rig sent to another
controller on the same bus is no longer taken for ours, and a set_ptt, set_freq
or set_mode whose acknowledgement goes missing is verified by reading the rig
back instead of being reported as a failure. WSJT-X and JTDX answer a failed
command with a Rig Control Error and drop the link mid-over — 98 keyings, 6 lost
acknowledgements, 2 dropped connections in one session. The check waits 700 ms,
not the poll's 150: the rig has just failed to answer twice because it was
retuning, and a short probe would fail for the same reason.

Auto-call is withdrawn — it duplicated DXHunter, which already answers decodes,
and two programs deciding that from one shack key over each other. The library
is kept whole and dormant; a guard in App.tsx makes sure a stored preference
cannot key a transmitter whose switch no longer exists.

Also:
  - the log rotates while running, not only at startup: the CI-V trace left on
    wrote 416 MB and nothing would have stopped it before the disk did. Closing
    it now releases the crash file too — the runtime keeps its own duplicate.
  - the interface zoom announces itself, with a badge, a click back to 100% and
    a View menu; Ctrl+wheel and Ctrl+0 always worked and nothing said so.
  - no more elastic bounce, and no swipe-to-navigate out of the app.
  - Edit QSO: your own TX power and the contacted station's extended locator
    were saved and written back with no box to set them.
  - FT decodes: continents are a multiple choice; a compound MSHV message that
    answers two stations in one line is recognised as addressed to you.
2026-08-23 01:16:26 +02:00
rouggy cb430a22ee feat: Ultrabeam over USB, Paper QSL from the awards grid, per-role schemas
Ultrabeam on a serial port never worked, and three faults were stacked so
each hid the next:

  - Stop() did not wait for the poll loop, so a stopped client kept the COM
    port. Every later client then failed with "Serial port busy" — the
    program holding it being OpsLog itself.
  - startUltrabeam tore the old client down CONCURRENTLY with starting the
    new one, and "Test connection" built a second client on a port already
    ours. Harmless over TCP, fatal on a port with one owner.
  - A silent serial port returns (0, nil) and bufio retries that a hundred
    times: a 4 s timeout became ~7 minutes of a frozen poll loop logging
    nothing.

The controller then answered at once. Confirmed on hardware: the USB cable
presents TWO COM ports, only the second reaches the controller, and only at
19200 baud — so the speed is pinned in code (an FTDI cable opens at any
speed, and a wrong one is indistinguishable from a dead controller) and the
port field says which one to pick. The first exchange after each connect is
hex-dumped, which separates silence from a wrong baud from a misread frame.

Databases now carry only the tables their role needs. Every target used to
get the whole migration set, so a shared MySQL logbook grew settings and
station_profiles tables nothing ever wrote to — an operator inspecting the
server could not tell which copy was authoritative. Statements are filtered
by role, unknown tables are kept in both (fail-safe), and existing databases
are cleaned once, dropping only EMPTY tables. Settings → Database gains a
Compact button, since SQLite frees pages inside the file and never shrinks it.

Also:
  - Awards: the callsigns behind a cell open the QSL Manager on Paper QSL,
    searched, ready for the card dates.
  - The record button no longer goes missing after an update: whether manual
    recording is possible is a per-profile question that was asked once, at
    startup, before the profile was known.
  - Alert rules and filter presets confirm that they were saved.
  - Spot clicks on the radio panadapter carry the POTA park into F3.
  - The build gate is re-checked wherever the active callsign can change; it
    ran at startup alone, and a fresh install has no callsign then.
2026-08-22 14:07:00 +02:00
rouggy abfed4afa2 chore: release v0.26.4 2026-08-22 08:35:49 +02:00
rouggy d48420485f chore: release v0.26.3 2026-08-21 23:28:55 +02:00
rouggy 0cd243fe00 chore: release v0.26.2 2026-08-21 18:21:33 +02:00
rouggy c49faf9a14 fix(antenna): pick the SteppIR's serial port from a list
The COM port was a bare text field — the only serial device in the app without
a port list, and typing one by hand gave no clue when it failed.

A Combobox rather than the Select the other devices use, deliberately: the port
of a USB adapter that is not plugged in does not appear in any list, and
refusing a typed value would mean the antenna cannot be configured until the
adapter is in. Detected ports are offered, anything else is still accepted, and
the value is trimmed and upper-cased on the way in.

The failure itself was already logged by the SteppIR client ("cannot open COM7
@ 4800 baud"); what was missing was the line above it not claiming the antenna
had connected. That is fixed separately.

Carries the 0.26.2 changelog entries for this and the three preceding commits —
one file, and splitting it four ways would have said less than this does.
2026-08-21 14:36:07 +02:00
rouggy e6889caae9 chore: release v0.26.1 2026-08-21 01:43:14 +02:00
rouggy e3b7a35e2c fix: stop losing decodes, hanging on exit, and wedging the rig link
Three faults an operator's log finally made visible, plus the interface
work that came out of the same session.

Reliability:

- UDP events were dropped on backpressure without a word. A period hands
  over twenty-odd decodes at once, and one slow write to the radio was
  enough to fill the queue — so a decode simply never appeared, and the
  only detector was the operator comparing the panel with JTDX. The drop
  is now counted and logged, panadapter spots went to their own goroutine
  so the radio can no longer hold the decode stream up, and the queue is
  deep enough for a full period.

- The CAT manager waited for its poll loop with a bare <-done. A loop
  wedged in a serial read then blocked every later restart inside Start,
  before it could even try to connect: the rig stayed dead, no line was
  written anywhere, and only killing the process recovered it. The wait
  is bounded at ten seconds and says what it abandoned and why the next
  connect may fail.

- Shutdown had no logging at all, so a hang left nothing to go on and a
  process the operator had to kill — which then blocked the restart after
  an update. Every step is logged, and a watchdog forces the exit if one
  of them never returns.

Auto-call:

- A QSO in progress is now held by OpsLog itself rather than inferred
  from the sender's Status. The moment WSJT-X/JTDX dropped the DX call or
  the Enable-Tx flag between overs, the exchange looked finished and the
  next CQ was answered, interleaving two and then three QSOs on one
  slice. Released on log, on halt, on taking over, and by a watchdog.

Cluster console:

- Replies to a command were buried under the spot flood; a Replies
  toggle hides the DX spots, which the list above already shows.
- Twelve named command buttons beside the input, configured in
  Settings -> Cluster; a button with no command is not drawn.
- Following the tail is now an explicit switch, and sending a command
  re-arms it. It used to measure "am I at the bottom" AFTER committing
  the new lines, so a ten-line reply looked like the operator had
  scrolled up and was never followed — the one case it exists for.

Awards:

- An award can name NO field. The matching controls disappear with it
  and only hand-assigned references count, which is the only thing that
  can feed a reference like WWBOTA. A test pins that nothing else is
  scanned.
- WWBOTA added to the catalogue with its 31 342 references.

Elsewhere: the rotor widget's Stop button acknowledges the press like
the direction presets already did, and the docked band map can be
switched to fit-to-band from its own header.
2026-08-21 01:07:10 +02:00
rouggy 1e507225dd chore: release v0.26.0 2026-08-20 17:53:55 +02:00
rouggy 6ed38014ed chore(decodes): changelog entries for the FT decodes panel 2026-08-18 11:17:30 +02:00
rouggy f0e00c63a3 fix(import): "fill my station fields" fills the station callsign too
STATION_CALLSIGN was the one field the option deliberately skipped, on the
grounds that stamping the active call could re-route a mixed-call log.

That protected nothing. The same option already writes this profile's grid,
rig, antenna, city and postal address onto every record it finds blank — it
has assumed "this log is mine" long before it reaches the callsign. And the
thing that actually keeps a multi-op log intact is that a record CARRYING a
station callsign is never touched, which has always been true and still is.
Withholding it only meant the option quietly failed on the one field an
operator goes and checks afterwards, leaving imported QSOs with no station
call at all — invisible in the ADIF they export, and unroutable for LoTW
and Club Log.

Counted and logged: "did it fill the callsign?" is the first question after
an import, and the log is where it gets answered.
2026-08-18 11:08:45 +02:00
rouggy 628d1e8490 fix(clublog): use OpsLog's own application API key
The embedded key was registered to XV9Q, not to OpsLog. Not a cosmetic
detail: Club Log identifies the client software by that key, so every
OpsLog upload in the world was attributed to that callsign. Its owner
received the abuse warning OpsLog earned when the on-close sweep was still
posting hundreds of QSOs through the realtime endpoint - and a revocation
aimed at them would have cut Club Log uploads for every user of this
program at once.

G7VJR issued a key for "OpsLog" on request. Same mechanism, same UX: the
key identifies the software, the operator still supplies their own e-mail
and password, so it authorises nothing on its own.

Club Log asks that it not be published in source code. The source is on a
private remote and only the built exe is released, but it remains
recoverable from that binary by anyone who looks - as it is for every
logger that embeds one. It is an identifier that can be attributed, not a
secret.
2026-08-18 10:10:33 +02:00
rouggy c48edd7898 chore: open the 0.26.0 changelog block 2026-08-18 06:13:32 +02:00
rouggy 9599c3e0b9 chore: release v0.25.9 2026-08-18 05:09:04 +02:00
rouggy a81125eab1 fix(icom): a set whose acknowledgement is lost is sent once more
Extends to frequency and mode what PTT already had. A missing FB is not a
missing command: the rig acts on the frame as it decodes it, and what
expires is our wait for the answer, on a bus shared with the rig's own
transceive updates. JTDX in "Split: Fake It" moves the dial and the mode
immediately before every key-down, so those acks queue behind each other.

Losing one is fatal to the client rather than merely untidy: rigctld answers
RPRT -9, JTDX reads that as losing rig control and tears the connection down
mid-over. An operator's log shows three set_freq failures and one set_mode,
each followed within 300 ms by a fresh rigctld client -- and shows the PTT
resend rescuing an over that would otherwise have ended there.

Opt-in per caller rather than folded into exec: only a command that says
"be in this state" can be repeated safely, and a relative one must never
come through here.

The acknowledgement loss itself is still unexplained. Every failure in that
log is preceded by a state read reporting SSB on a rig in DATA, which points
at CI-V frame desync rather than a slow rig, and needs a trace to pin down.
2026-08-17 16:23:54 +02:00
rouggy 7be6f64596 chore: release v0.25.8 2026-08-17 13:18:32 +02:00
rouggy 0bab7f05b9 feat(relays): accept a self-signed certificate on a generic HTTP board
HTTPS to a relay board could not work. Nearly every board that offers it signs
its own certificate — there is no authority anywhere that could have signed it —
so the request failed verification before it left.

A checkbox, per board, off by default. Not a blanket switch, because the other
HTTPS case is real and opposite: a board reached from outside through a proxy
with a genuine certificate, where verification is the only thing standing
between an antenna switch and the internet. Same setting, two boards, different
answers.

Off by default is only safe if the failure explains itself, so a certificate
error now names the box to tick. Go's own "x509: certificate signed by unknown
authority" is accurate and tells an operator nothing about what to do next.

Shown only once an https:// URL is actually in the board's configuration. A
board on plain HTTP has no certificate to argue about, and an option that cannot
matter yet is one more thing to wonder about.

The flag joins the driver cache key: ticking it has to rebuild the driver, or
the cached one would go on refusing the certificate with the verifying client it
already holds.

The boards that take a bare host — WebSwitch, KMTronic — keep verification. An
https:// typed there is the proxy case by construction, since they default to
plain HTTP on the LAN.

Three tests against a real self-signed TLS server: accepted with the box,
refused with a message naming it without the box, and one board's setting not
leaking into another's.
2026-08-17 10:57:29 +02:00
rouggy dc898ce2af fix(amps): combined amplifiers are commanded together, power level included
Two faults in the combiner coupling, both reported from the operating position.

THE POWER LEVEL WAS NEVER COUPLED. ON, OFF and OPERATE fanned out to the group;
L/M/H did not — it was simply the command nobody had linked. Two combined
amplifiers left at different power levels feed the combiner unevenly, which is
the thing the coupling exists to prevent.

THE COMMANDS DID NOT LEAVE TOGETHER. The second amplifier was commanded only
once the first had answered, and an SPE answers over its own link in its own
time. The combiner heard power appear on one input before the other and beeped
about it, on every OFF and every ON.

Each target now gets a goroutine, all parked on one channel until every one is
ready; closing it releases them together. That is the difference between "start
one, then start the other" and "both leave at once" — they have separate clients
and separate connections, so nothing downstream re-serialises them.

It matters most on the power level, which is not one command at all: an SPE has
no "set level", so the driver taps the POWER key and waits for the amp to report
the new one before tapping again — up to three taps, up to two seconds each. One
after the other, the pair would sit at different levels for six seconds.

A single amplifier still runs inline: no goroutine, no barrier, nothing new to
go wrong for the operators who have one amp. The one that was clicked stays
first, because its failure is the one worth reporting.
2026-08-17 10:42:19 +02:00
rouggy e5c9ca1a7d fix(rotator): the compass shows the heading it already knows
Opening Station Control left the compass blank for a second or two while the
amplifiers, relay boards and power supply filled at once.

Nothing was slow. The status bar keeps the shared heading loop running, so when
the compass mounts there is already a tick pending — up to the full three-second
idle interval away — and the new subscriber simply waited out the rest of it.
The heading was known the whole time and had nowhere to be read from.

The last heading is now kept and handed to whoever subscribes next. That matters
more on the Alpha SPID this was reported on than it would elsewhere: every poll
is an open, a read at 600 baud and a close, so even fetching immediately on
mount would not have been immediate.

In a microtask, so a subscriber is never called back before subscribeRotorHeading
has returned to it.
2026-08-17 10:32:06 +02:00
rouggy 21a0d560de feat(awards): a reference's number can be corrected in the editor
The one field the editor would not let you touch, and the one that was wrong on
WAJA. Every other property of a reference — its name, pattern, entity list,
validity window — was editable; the code was rendered readOnly, so correcting a
number meant deleting all 47 references and importing a new list, throwing away
anything the operator had adjusted in it.

A rename in the store, not a delete plus an insert: everything the reference
carries travels with it, which is the whole point of correcting a number rather
than replacing an entry. A number already in use is refused — REPLACE INTO would
have let one reference silently swallow another, discovered much later as a
prefecture quietly missing from the list.

The typed code is held apart from the selection. The list and every field patch
key off the selected code, so editing it in place made the editor lose the
reference mid-edit.

SaveAwardReference now recomputes the log like Delete and Replace already did. A
reference's name is what the award column SHOWS for awards displaying by name,
and its pattern is part of what matches at all — so editing one changes rows,
and the grid was left showing the old label until something else happened to
trigger a pass.

Changelog: the three TCI-sharing lines are merged into one. The server and the
two fixes made to it while building are one unreleased feature, and an operator
only ever meets the finished thing. The TCI-client PTT line stays separate — it
is OpsLog driving a SunSDR, the other direction entirely.
2026-08-17 10:26:13 +02:00
rouggy 2941121f4b fix(awards): WAJA was numbered by the Japanese state, not by the JARL
The catalog carried Japan's civil prefecture code (JIS X 0401) — 01 Hokkaido,
02 Aomori, 03 Iwate, 04 Miyagi — where the award uses the JARL's own numbering.
The two agree on the first three prefectures and then part company on 35 of the
remaining 44: Tokyo is 10 to the JARL and 13 to the government, Niigata 08
against 15, Toyama 28 against 16.

The names were right throughout, which is why nothing looked wrong: the award
matches on the prefecture NAME in the QTH, so it counted exactly the right
contacts. Only the number against each one was wrong — and that number is what
an operator writes on a JARL claim.

Renumbered by name from the official JARL list, so everything else each entry
carried travels with it. That includes the Tokyo spelling pattern, which had to
move from 13 to 10; left where it was it would have been matching QTHs for
Saitama.

Two digits throughout, as the JARL prints them. Not cosmetic: the codes are
strings, so "1" sorts between "09" and "10" and the reference list appeared in
an order no published list uses.

Version 2 on the definition, so this actually reaches people. An operator who
has not edited WAJA gets it at startup; one who has is offered it, since their
work outranks ours. Nobody has to re-import by hand.

Reported with the official JARL chart alongside the exported award.
2026-08-17 10:17:28 +02:00
rouggy 6c75ff345b fix(tci server): split armed on the frequency asked for, in either order
Audit prompted by "are we sure the commands are implemented — split, Fake It,
Split rig?". The rigctl server is complete and hardened; the TCI one, three days
old, had reintroduced a bug rigctld had already paid for.

A client working split says two things — where to transmit, and that split is
on — and nothing obliges it to say them in that order. A write to channel B
while the rig was still simplex was DISCARDED, on the sound principle that
preparing a transmit frequency is not a request to QSY. But then the split was
armed on whatever the transmit VFO held, which is the receive frequency: the
operator transmits straight onto the DX while their software shows exactly what
they asked for. The frequency is now remembered and used when the split arrives,
which is what rigctld does with set_split_vfo / set_split_freq.

Two more from the same source:

Asking for a split state the rig is already in touches nothing. A client in Fake
It uses no split but still says so to be sure, and answering an error to a
request that was already true is what made JTDX abandon a transmission a second
into the frame through the rigctl server.

A repeated PTT command is not re-sent. One client restated it sixteen times a
second, and the Flex's own "xmit 1" was overwritten between two of them inside a
millisecond. The same radio sits behind this server — the operator reporting
this is on the Flex API backend.

Fake It itself needs nothing but channel A, and now has a test saying so.
2026-08-17 10:00:57 +02:00
rouggy d5e25244ee fix(tci server): announce transmit permission, and log what the client sends
MSHV's PTT test does nothing against the TCI sharing server.

The initialisation block never carried TX_ENABLE. The document files it under
unidirectional control rather than initialisation, so it was missed when the
block was written from §4.1 — but its own note says it is "sent to the client
when connected", and that is the point: a client that models transmit
permission starts out assuming it may NOT transmit. Without it MSHV never even
tries, so nothing arrives to relay and there is nothing to see at either end.

Sent as true always. OpsLog is not what decides — the radio behind whichever
backend is connected does, and its refusal already travels back through SetPTT
into the log.

TX_FREQUENCY goes with it, at connect and whenever the transmit frequency
moves. It is the command a client showing "TX 14.200" reads; channel B alone
left that stale.

And every command a client sends is now logged. This is the only evidence there
will ever be about a program on someone else's machine: "the PTT test does
nothing" cannot be answered without knowing whether MSHV sent trx at all, and
in what form. Cheap — TCI is event-driven, a client speaks when the operator
does something — and capped at 200 lines per connection so one that does poll
cannot quietly fill the log.

If this was not the cause, the next report answers it in one line rather than
another round of guessing.
2026-08-17 09:39:02 +02:00
rouggy 4095455e66 fix(tci): a refused PTT is reported instead of vanishing
"PTT via CAT does nothing on TCI." What OpsLog sends is right — trx:0,true; is
the documented command and the same one the reference clients send — so the
command was going out and the radio was discarding it.

ExpertSDR announces transmit permission with TX_ENABLE: on connect, and again
whenever the band changes, "in case transmitter permission was changed" (§4.3).
While it is false the radio simply IGNORES trx. OpsLog never read that command,
so there was nothing in the log, nothing on screen, and a dead key.

Now the permission is tracked and SetPTT refuses out loud, naming where to look:
the frequency must be inside a transmit band and TX enabled in ExpertSDR. The
refusal travels the path that already exists — Manager.SetPTT to pttKey, which
logs it and hands it to the UI.

Silence is not a "no". A radio that never mentions TX_ENABLE — an older
ExpertSDR, or another program speaking TCI — is not treated as refusing: we key
and let it decide. Permission is also forgotten on connect, so a refusal
remembered from a band since left cannot block PTT until a restart.

This may not be the operator's own cause, and that is the other half of the
change: if it is not, the log now settles it in one line. cat: TCI: → trx:0,true;
present means the command left OpsLog and the radio ignored it for a reason it
has not told us; absent means the fault is on this side.
2026-08-17 09:30:36 +02:00
rouggy 3f95763ca6 feat(lookup): a cache TTL of 0 switches the cache off
Wanted for the case where the answers are moving: an operator correcting their
own QRZ record, or chasing a DXpedition whose page changes during the operation,
otherwise waits out thirty days before OpsLog will ask again. Clearing the cache
by hand works once; this is the setting for a whole session.

Nothing is read from it and nothing is written to it — rows stored while it is
off would only sit there going stale, waiting for the day it comes back on.
Switching off is NOT clearing: what it already holds stays, and the Clear cache
button remains the way to throw that away.

Two distinctions the code now has to keep, both load-bearing:

An EXPLICIT stored zero is off; an ABSENT key is the thirty-day default. Every
operator who has never opened this setting has nothing stored, and reading that
blank as a zero would silently switch the cache off for all of them.

The CONSTRUCTOR's zero is still the default, not off. At startup the settings
have not been read yet, and beginning with no cache would hammer the provider
for the first seconds of every launch. Only SetTTL, called once the operator's
settings are known, can switch it off.

A negative lifetime is meaningless and is ignored rather than rounded into
either meaning.

The input had to change too: it derived its value from the stored number on
every keystroke, so the box could not be emptied — and 0 was unreachable
outright, since parseInt('0') || 30 is 30.
2026-08-17 09:21:12 +02:00
rouggy 72ec3cbb97 feat(cat): share the rig over TCI as well as Hamlib — one or the other
internal/rigctld exists because Windows gives a COM port to ONE process: the
moment OpsLog talks to the radio natively, nothing else can. It answers the
programs that speak Hamlib NET rigctl. This answers the ones built around Expert
Electronics' TCI instead — and it answers them whatever radio is connected,
because it sits on the same backend-agnostic Rig interface. An operator with an
Icom or a Yaesu can now hand a TCI-only program a working rig.

One server or the other, never both. They answer the same questions about the
same radio, nothing speaks both, and a second listener is only a second thing to
go wrong.

Written against the official TCI Protocol document (ExpertSDR3/TCI, 12 January
2024, MIT — downloaded and read, not recalled): the initialisation set of §4.1
in its documented order, and the argument order of every command from §4.2. A
client will not proceed past connect without that block, which is why it is
written out in full rather than stubbed.

The one dangerous detail is the VFO mapping. TCI's channel A is where you
LISTEN and channel B where you transmit — the opposite way round from OpsLog's
RigState, which follows ADIF. Getting that backwards would put a station on the
DX's own frequency, so it is pinned in both directions by a test, and RxFreq was
added to the adapter rather than inferred.

Writing channel B while the rig is simplex is ignored: the client asked to
prepare a split transmit frequency, not to QSY, and a logger doing that on every
spot click would drag the operator off the station they were listening to. A
backend that cannot split still refuses out loud.

Only changes are pushed. TCI clients redraw on each command, so re-sending an
unchanged frequency four times a second makes a VFO readout flicker and fights
the operator's own tuning.

Nine tests, no socket needed — the protocol is the decision, not the transport.
2026-08-17 02:35:21 +02:00
rouggy a8bca8c316 feat(awards): an entity that IS one island group fills its own IOTA reference
QRZ carries <iota> only for the operators who filled it in, and most have not.
But for 99 entities the reference follows from the entity alone — a station in
Ascension is on AF-003 whatever its callbook record says — and the entity is
known for every callsign from cty.dat, with no callbook at all.

So this reaches the operator with no QRZ subscription and the station that has
never touched a callbook, and it lands before the contact is logged, which is
when a reference is worth having.

Filled ONLY when the callbook gave nothing: an operator who typed a reference
knows something a table cannot — an IOTA-heavy entity, a rare island being
activated — and that still wins, as does one picked by hand on the entry.

The table is the IOTA programme's own dxcc_matches_one_iota.json, which lists
exactly the entities that map to ONE reference. France is not among them: a
French station is usually on the mainland and on no island, and guessing would
put a reference on hundreds of contacts that earn none.

Held as a table rather than a download — 3.5 kB that changes when an entity
appears, so fetching it daily would buy nothing and would fail exactly where a
portable station usually is. The header says where it came from and how to
refresh it.

Follows 747c2b9 and eab11db, which read the callbook's own tag.
2026-08-17 02:26:52 +02:00
rouggy 8b75166dbe chore: open 0.25.8
Version constants stay at 0.25.7 — the release script bumps them.
2026-08-17 02:20:56 +02:00
rouggy 491546c7f4 fix(tci): one marker per callsign on the panorama, not one per spotter
Spot mirroring drew the same station two or three times, a few hertz apart.

Not a loop in the spot pipeline — one cluster line produces exactly one
SendSpot. It is that a popular DX station IS spotted two or three times, by
different operators inside the same minute, and no two of them agree on the
frequency to better than a few tens of hertz. This backend assumed ExpertSDR
replaced a spot bearing a callsign it already held, and said so in a comment;
it keys on the frequency too, so each of those became its own marker and stayed.

The FlexRadio backend has always done this properly (spot remove before spot
add, "one live spot per call"). TCI now does the same: the frequency drawn for
each call is remembered, a re-spot within 500 Hz sends nothing at all, and one
further away deletes the old marker before drawing the new one — so a station
that really moves still moves, instead of collecting markers.

SPOT_DELETE was not in the protocol document this backend was written from.
Confirmed before use against ars-ka0s/eesdr-tci, an independent TCI library that
lists SPOT with 5 arguments, SPOT_DELETE with 1 and SPOT_CLEAR with 0 — the
other two matching exactly what already works here, which is what makes the
third trustworthy.

The memory is cleared where Connect sends spot_clear. Left standing, it would
suppress the next spot for every remembered call as "already drawn" onto a
panorama the radio had just emptied — spots would quietly stop appearing after
a reconnect until each station changed frequency.

Five tests on the decision, which is split out from SendSpot so it can be
checked without a radio.
2026-08-17 01:57:11 +02:00
rouggy 91b21a4a36 feat(sync): the folder loop, the hooks and the panel — it can be switched on now
The three layers underneath were already there and unreachable: the change-log
format (7d664bd), the identity column (724e68b) and the no-backfill decision
(c48294b). This is the wiring that gives the operator a switch.

Settings, all profile-scoped, because each profile can point at its own logbook:
the folder, this PC's name, the machine id minted once from it, the per-peer read
offsets and the tie-break counter. Scoping the machine id is what keeps two
profiles sharing one folder from writing two logbooks into one file.

Three hooks. Add and update publish asynchronously, down with the rest of the
after-the-fact work — a folder on a network share can block for seconds and a
contact belongs on screen long before another machine hears about it. Deletion
publishes SYNCHRONOUSLY and BEFORE the row goes, for the same reason
deleteRemoteCopies does: once it is gone its identity is gone with it and the
tombstone names nothing.

The apply path uses the repository directly and never AddQSO/UpdateQSO/DeleteQSO
— those publish, and a change applied here would be written straight back out,
two machines echoing each other for ever.

Saving writes a probe file to the chosen folder rather than asking whether it
exists. A read-only cloud folder, or a share whose credentials expired, exists
perfectly well and would swallow every contact in silence; if the probe fails the
switch goes back off instead of sitting on while nothing is written.

The panel is mostly status, and deliberately: every part of this runs on another
machine and on a sync client OpsLog cannot see, so "it is not working" has to be
answerable from the settings page — which PCs are in the folder, when each last
logged, what is waiting unread.

Four tests on the apply path, the middle two being the ones that matter: an edit
made on the other PC lands on the copy already here, matched on the contact
itself, instead of becoming a second row — that is what makes the no-backfill
decision safe — and a contact with the same station on another band stays a
separate contact.
2026-08-17 01:34:00 +02:00
rouggy 747c2b9105 feat(lookup): read QRZ's island reference and fill the IOTA award
QRZ's XML carries <iota>EU-048</iota> for an operator on an island, and OpsLog
read past it. Wired end to end: the provider, the lookup cache (a column, like
web and zip before it), and the entry's award references.

It matters more here than the same field would for another award. There is no
live "who is on an island right now" feed anywhere — POTA has one and that is
what OpsLog matches spots against; SOTA has one behind conditions; IOTA
publishes only static lists. So the callbook record is the practical source, and
it is known BEFORE the contact is logged, which is when a reference is useful.

The reference goes in as an IOTA award reference, exactly as one picked by hand,
so the existing path carries it to the qso.iota column on save.

Two limits, both deliberate. A reference the operator typed or picked WINS: a
callbook entry can be years out of date, and the operator in front of the radio
has just been told where the station is. And the value must look like an IOTA
reference — two letters, a hyphen, three digits — because writing anything else
into the award makes a reference no list contains, which counts for nothing and
has to be found by hand later.
2026-08-16 23:22:37 +02:00
rouggy 93732ee563 fix(entity): show the QSO's own entity, and date the ClubLog exception
Two faults behind one screenshot: 3Y0K, recorded in the log as Bouvet Island,
showing the Antarctica matrix.

SELECTING A QSO now shows what that QSO records. The panel asked WorkedBefore
with no DXCC hint, and a hint of zero makes the backend resolve the entity from
cty.dat and the ClubLog exceptions AS THEY ARE TODAY — right for a live contact,
wrong for one being looked at in the log. The repo's own "infer from past QSOs"
path never ran, because the hint was no longer zero by the time it got there.
Hence Antarctica, and "5 QSOs with this entity" against "11 with this call":
two different entities, one of them nobody had asked about. The selected row's
dxcc now travels with it and is passed as the hint.

Browsing the log shows what the log says, even where the log is wrong.
Correcting an entity stays a deliberate act — right-click, Update from ClubLog.

BACK-ENTERING A QSO now resolves the exception at the CONTACT'S date. An
exception carries a validity window and a DXpedition's window closes: 3Y0K typed
months later, with the activation's own date in the form, was resolved against
today, matched nothing, and fell back to cty.dat. Both callers pass the date
they already hold — the entry strip's, and in the editor the record's own.

The date is trusted to move the resolution BACKWARDS only. A half-typed
"2026-0" must not send the lookup to the year 20, and a mistyped future date
must not resolve against a window that has not opened; both fall back to now.
Midday rather than midnight, because a window given in whole days is inclusive
of its end date and 00:00 sits exactly on the boundary.
2026-08-16 21:34:15 +02:00
rouggy 5293bb18c5 fix(i18n): seventeen strings had drifted into English only
Reported from a photograph of a French screen: "Spot lifetime" and "Chase new
grids" still in English in the DX Cluster settings. Diffing the two dictionaries
turned up fifteen more — including the ENTIRE update panel, which is why an
operator who reads French had nothing in French to react to when a new version
appeared.

All seventeen translated. Both dictionaries now hold 2685 keys with no
difference either way.

Every user-visible string ships in both languages: that was a rule, and until
now only a rule. A test parses the two dictionary literals and compares their
keys, so the next one is caught by `go test` instead of by an operator
photographing their own screen. Verified it fails when a key is removed.

A key missing from one side is not a blank — it falls back to the key itself,
so the interface reads "clu.spotTtl" where a label belongs, or keeps the English
text, which looks deliberate and is not.
2026-08-16 18:25:26 +02:00
rouggy 14ac73028e fix(worked-before): a prefixed call is one operator, not a whole country
Reported from a screenshot: working ZA/OE8NDR, the worked-before list showed
ZA/IZ2DPX and ZA/IW2JOP beside him and the header counted all four as contacts
"with this call".

callMatch folded portable forms together by taking the part before the slash.
That is right when the slash carries a suffix — RK3DWA/3, RK3DWA/P are one
person — and exactly wrong when it carries a prefix: ZA/OE8NDR became the
station "ZA", and the predicate `callsign LIKE 'ZA/%'` then selected every other
visitor to Albania.

The operator's own call is now picked out properly: drop the known qualifiers
(P, M, MM, AM, QRP, a bare call-area digit) and of what remains take the longest
part — a country prefix is short by nature, ZA, F, KH6, VP2E, and a callsign is
not. The predicate matches the prefixed forms too, so ZA/OE8NDR and a plain
OE8NDR still find each other, which is the whole point of the fold.

A base under three characters falls back to an exact match: a malformed entry
must not produce a LIKE that selects half the logbook.
2026-08-16 18:08:28 +02:00
rouggy b5a88ee5a2 fix(awards): hide Missing refs where it cannot mean anything
"In this award's scope but with no reference" needs a scope to be in. On a
worldwide reference award — POTA, SOTA, IOTA, WWFF — every contact anywhere
would qualify, so the backend returns nothing and the window says it found
nothing. The button was there regardless, and could only ever open that.

It now appears only for an award scoped to a DXCC entity, which is what the
help text underneath used to have to explain. Better than what I did first,
which was to make a useless screen fast.

Kept from that: the assign dropdown is searched rather than scrolled above 300
references, and the reference list is not fetched until there are rows to
assign it to. Both still bite on a scoped award with a long list — Russian
districts, the bigger European ones.
2026-08-16 18:04:34 +02:00
rouggy e81500f809 fix(awards): Missing refs froze the window on a big reference list
Reported as POTA: missing references, and it hangs.

The Missing-refs modal builds a dropdown of every reference the award has, one
menu item each. A POTA log with the park list imported holds tens of thousands
of them, and putting that many items in the DOM stops the window answering.
Russian districts and the bigger European lists are the same shape.

Two things, and the second is the sharper one.

The list is now searched rather than scrolled: above 300 references a filter box
appears beside the dropdown, and the menu renders at most that many, saying how
many it is holding back. Nobody scrolls to K-4521 — they type it.

And the modal no longer fetches the references at all until there is something
to assign them to. Missing-reference detection needs a DXCC scope, so a
worldwide award like POTA always has zero rows here and the modal says so — it
was loading every park behind that message, for a dropdown that could not be
used for anything. The freeze happened on a screen with nothing to offer.

Whether this is the freeze that was reported I cannot say from here; it is a
freeze on exactly that screen, for exactly that award.
2026-08-16 17:18:45 +02:00
rouggy 37805fe3ed perf(awards): build the logbook snapshot once, not once per caller
A field log showed three pulls of the same 123 615 QSOs inside ten seconds, the
Go heap going 725 MB → 2213 MB → 2539 MB. It is released after the idle TTL, so
not a leak — just the same work done three times with all three results alive at
once.

The cache lock was released before the logbook was read, so every caller that
arrived during a build missed the cache and started its own. Opening the Awards
panel does exactly that. One builder at a time now, with the usual re-check
after taking the lock: the second and third caller wait out the seconds they
were going to spend anyway, minus two round trips to the database.

The slice is also sized from the previous build. Growing to 123 000 structs by
doubling copies the whole thing a dozen times and holds the old and the new
array together at each step, on the largest object OpsLog keeps.

Also, the settings panel registry. The hook trap that broke the window when the
power-supply panel was opened was headed off by a comment, and the comment did
not survive contact with the next panel — so it is now structural. PanelHost is
a module-scope component that calls the selected panel and is keyed by section:
hooks inside a panel land in a component context that persists, section changes
remount it so each gets a fresh and consistent hook list, and no panel state
leaks into the next.

Rendering the panels as <Panel /> instead — the obvious refactor — would have
been wrong: they are nested inside SettingsModal and close over its state, so
each parent render makes a new component TYPE and React would unmount and
remount the panel on every keystroke.
2026-08-16 14:40:18 +02:00
rouggy 7578e49573 chore(changelog): open 0.25.7
v0.25.6 went out with its nine entries; the block is byte-identical to the
tagged one. The version constants are left alone — the release script is the one
source that bumps them, and touching them here would make its "release commit
already exists" check misfire.
2026-08-16 14:20:22 +02:00
rouggy 191e92ad62 perf(rotator): one adaptive heading poll for every controller type
Asked whether the faster poll applies to all the rotator backends. It does —
GetRotatorHeading is one binding over PstRotator, Rotator Genius, GS-232/ARCO,
DCU-1 and SPID alike, and it reads only the ACTIVE rotor, so two towers do not
double it. But counting what that costs turned up two things worth fixing.

Every backend builds a fresh client per call — spid.New, gs232.NewSerial,
dcu1.NewSerial, rotgenius.New — so one poll is one OPEN and CLOSE of a serial
port or a TCP connection, not a read on a link already up. And the status bar
and the Station Control compass each ran their own interval against that same
binding, so with the tab open the controller was asked twice over. At the 700 ms
I had just set, that was nearly three port opens a second on a 600-baud line.

Both now share one loop, and it adapts: 500 ms while the position is changing,
3 s once it has been still for six seconds. These controllers do not report
"moving" — a SPID answers a position and nothing else — so it is inferred from
the position itself, and held briefly after the last change so the tail of a
movement stays smooth. Commanding a move, a stop, or switching rotor polls at
once, so the needle starts sweeping on the click.

A slow controller cannot stack requests behind itself either: at 600 baud a SPID
reply takes a fifth of a second on the wire alone, and a port still open from
the last poll cannot be opened again.
2026-08-16 13:39:23 +02:00
rouggy f405e71d7d fix(spid): a Rot1Prog takes three digits, so every target went the wrong way
Field report from a tower: on a RAK/RAU in Rot1Prog, every commanded heading
made the antenna want to turn nearly a full circle ANTICLOCKWISE — 0°, 90°, any
of them — while the heading readout, the stop button and everything else worked.

BuildSet framed the four-digit Rot2Prog azimuth for both dialects. A Rot1Prog
reads three: its replies are three digits in a five-byte frame, and its command
field matches. So 90° went out as "0450" and was read as 045 — 45 − 360 = −315°.
Every target landed 360° low, which is why it was always anticlockwise and
always nearly a full turn. The operator's own guess, that OpsLog was in 720°
mode, was the right instinct in the wrong place: the fault is a decimal shift,
not a range.

The round-trip test added here is the one that would have caught it without a
tower — every degree of the circle through the command builder and back through
the reply parser, which must return the degree that went in. The frame tests
pinned the Rot2Prog form against the reference and said nothing about the other
dialect.

Two more from the same report. A rotator test that only READS the heading — SPID,
ARCO, DCU-1 — said "Packet sent, the antenna should swing to north, check
PstRotator's UDP listener", naming a program not in the path for a move never
commanded; it now says the controller answered and nothing was moved. And the
compass polled every three seconds, so a turning antenna moved the needle in
steps of about thirteen degrees; the heading now has its own 700 ms tick while
the relay boards and the antenna controller stay at three seconds.
2026-08-16 13:31:00 +02:00
rouggy 8683a450a7 feat(psu): switch a Modbus RTU bench supply from OpsLog
The manufacturer's document arrived, so this is no longer guesswork: 9600 8N1,
function codes 03 and 06 only, and a register map with the output on/off at
0x0001, the measurements at 0x0010…0x0013 and the set points at 0x0030/0x0031.

ONE REGISTER IS WRITTEN — 0x0001, the output. The map also exposes the voltage
and current set points and the three protection trip levels as writable, and
none of them belong to a logbook: a wrong value there is 30 V where a radio
expected 13.8, or a trip level lifted on a supply feeding an amplifier. They are
read and displayed instead, next to the measured values, which is also how an
operator sees at a glance that the supply is on and the radio is drawing nothing.

The wire layer is tested where it can be. CRC-16/MODBUS is pinned against its
published check value — the CRC of "123456789" is 0x4B37 — which fixes the
polynomial, the initial value, the reflection and the absence of a final xor all
at once; the rest of the protocol is checked frame by frame against the manual,
including the byte order of the CRC, an exception reply told apart from a broken
line, and a reply from another slave on the bus refused. The write echo must
match the value sent: it is the only confirmation the output really switched,
and accepting the frame without it is how a radio ends up dark behind a green
light.

Framing follows the manual's own rules: 3.5 character times of silence between
frames (4 ms at 9600), and a frame is over when the line falls quiet — Modbus
RTU has no terminator, and a serial read that times out returns (0, nil) here,
so the reader is built on a deadline and a quiet-time rather than on an error
that never comes.

Untested against hardware — nobody here has the supply.
2026-08-16 13:15:55 +02:00
rouggy 9f8e3c73d9 fix(udp): OpsLog was re-tuning its own rig from its own broadcasts
Reported as JTDX "Fake It" causing CAT disconnections. Fake It is not the
cause — it is what made an existing loop fire, and a regression of mine from
this morning is what closed that loop.

The station has an inbound remote-call row and an outbound N1MM RadioInfo row
on the same port, 2241, so every RadioInfo datagram OpsLog sends arrives
straight back on the loopback. The remote-call parser strips XML tags and takes
the last token as the callsign: for a RadioInfo that is
<ActiveRadioNr>1</ActiveRadioNr>, i.e. "1" — and <Freq> became a tune request
for the frequency the rig was already on.

That was harmless only while <Freq> was misread. It is in tens of Hz, the parser
assumed MHz, every echoed tune failed "out of the 11-digit CAT range", and the
loop died on the error. Teaching it the unit (331db58) closed the loop.

Fake It shifts the dial for each over rather than using split, so every
transmission changed the state twice — and each change published a RadioInfo,
which came back as a set, which changed the state again. The log shows the dial
oscillating 24915000/24915500 three times in 200 ms, then "timeout answering
IF;" and the shared link down. Every over, all morning.

Two guards, because one was not enough to be sure: a RadioInfo payload is never
a remote-call request, and a callsign has a letter in it — so the next program
to broadcast its state on that port cannot drive the rig either. Reload also
names an inbound and an outbound row sharing a port, which is the arrangement
that permitted this and which no settings panel shows.
2026-08-16 12:25:41 +02:00
rouggy 423cf1f998 feat(relays): follow the entry Band selector when there is no CAT link
Relay automatic control and the band-change outbound rows both hang off the rig
state, which is right when there IS a rig: changing Band in the entry strip
pushes a QSY, the new state comes back through the CAT callback, and the relays
follow from there — which is why this works for anyone with rig control.

Without a CAT connection nothing is pushed and nothing comes back, so a station
whose rig OpsLog does not control changed band and the antenna switch sat
exactly where it was. Reported as automatic control not working; it was never
told the band had changed.

The entry selector now says so itself, but only when the CAT push did not
happen, and never when the band or frequency lock is on: a lock means the entry
is deliberately decoupled from the rig, and moving an antenna to match a contact
logged from last year is worse than doing nothing.

The frequency is passed as unknown on that path — a band selector gives a band
and nothing else, and rules written on a frequency RANGE are left alone rather
than evaluated against a made-up dial reading.

The de-duplication of "is this a new band" is now shared by both sources, so a
station that has both does not command its switch twice for one QSY.

Also: the same credit line as the QSL e-mail now closes the default recording
e-mail body, on the same terms — a default in the template, so a stored one is
untouched.
2026-08-16 11:15:56 +02:00
rouggy c0dc1bfcc4 feat(qsl): credit line at the foot of the default QSL e-mail
"Designed & sent by OpsLog — https://github.com/GregTroar/OpsLog/releases/latest"
now closes the default body, so a fresh install sends it without being asked.

Put in the TEMPLATE, not appended at send time. Two consequences, both of them
the point: an operator who does not want it deletes the line once and it is
gone, and one who has already written their own body never sees it appear —
a stored template is returned verbatim and the default is only the fallback.
Appending it at send would have made it unremovable, which is not a thing to do
to somebody's outgoing mail.

The link is the human release page. updateCheckURL sits next to it in update.go
and answers JSON, which is the easy mistake here — a correspondent who clicks
the credit gets a download page, and a test says so.
2026-08-16 11:07:06 +02:00